90 LXE Diagnostics
MX1 Reference Guide E-EQ-MX1RG-D
LXE Diagnostics
Note: Make sure there is a fully charged battery in the MX1 before beginning a diagnostic
process. When using a Docking Cradle power supply, make sure there is an
uninterrupted power source.
The MX1 comes equipped with several utility programs. These programs can be run to make
adjustments as indicated.
LXE does not recommend running these commands in a DOS window from any Microsoft
Windows application.
BBDIS35.EXE Battery Discharge Utility
Condition the 50 mAh NiCd Backup Battery mounted on the system
board. The battery discharge starts and when discharged switches to
backup battery charge mode.
BBTST35.EXE Backup Battery Test Utility
Indicates the current status of the backup battery and the voltage.
COMTST35.EXE Communication Port Utility
To diagnose the serial communication port, a simple loop back test
routine is included in this file. The figure showing how to build a loop
back plug is included in this chapter. The test results will read PASS or
FAIL. A failure is identified and described.
DISP35.EXE Display Utility
Activates every pixel on the display to verify functionality.
KEY2335.EXE Keyboard Utility
This utility performs a contact functional test of each key on the
keyboard. When activated, the key labels appear on the screen and then
each key, when initialized, clears the key label from the screen.
LXEF.EXE File Transfer Utility
Transfer files to and from a PC through either the MX1’s serial port or
IR port, as well as act as the agent for the Win32 Developer Toolkit
Application.
PARAM35.EXE Parameter Dump Utility
This utility collects the setup configurable parameters and lists them in
a text file.
SCU35.EXE Scanner Configuration Utility
Allows programming multiple scanners with the same data.
SETAPI_4.EXE Set An API Function
Runs an API call to set a mode or change a parameter.