Specifications

36
“4” - User
Red level for
selected colour
temperature
0xb4,
nn | “+” | “-” |
“r” | “R” |
“?”
Set the level of the red channel
for the selected colour temp. =
value/increment/decrement
Reset
Query
Red level for selected colour
temperature.
Range : “9””C”-“F””F”
Default : “E””C”
Green level for
selected colour
temperature
0xb5,
nn | “+” | “-” |
“r” | “R” |
“?”
Set the level of the green
channel for the selected colour
temp. =
value/increment/decrement
Reset
Query
Green level for selected colour
temperature.
Range : “9””C”-“F””F”
Default : “E””C”
Blue level for
selected colour
temperature
0xb6,
nn | “+” | “-” |
“r” | “R” |
“?”
Set the level of the blue channel
for the selected colour temp. =
value/increment/decrement
Reset
Query
Blue level for selected colour
temperature.
Range : “9””C”-“F””F”
Default : “E””C”
Graphic horizontal
resolution enquiry
0xb7 Horizontal resolution (in pixels)
in 3 digit hex number
“nnn” = horizontal resolution
Graphic vertical
resolution enquiry
0xb8 Vertical resolution (in lines) in 3
digit hex number
“nnn” = vertical resolution
Graphic horizontal
sync frequency
enquiry
0xb9 Horizontal sync frequency (in
units of 100Hz) in 3 digit hex
number
“nnn” = horizontal frequency
Graphic vertical
sync frequency
enquiry
0xba Vertical sync frequency (in units
of Hz) in 3 digit hex number and
1 char
“nnnc” = vertical frequency
nnn = 3 digit hex
c= “i” or “p”
interlace or Progressive
0xba added the interlace(i)
or Progressive(p) feedback.
OSD status
enquiry
0xbb Status of OSD “0” – OSD turned off
“1” – OSD turned on
OSD turn off 0xbd Turn off the OSD. “1” – successful.
Wide Screen
Mode Selection
0xd9,
“0” | “1”| “2”
“r” | “R”
“?”
Wide Screen Mode
Reset
Query
“0” – Normal Mode
“1” – 1280x768
“2” – 1366x768
Backlight
Brightness control
0xe0,
nn | “+” | “-” |
“r” | “R” |
“?”
Set Backlight =
value/increment/decrement
Reset
Query
Set backlight brightness to “10”
Æ 0xe0 0x31 0x30
Range : “0”“0”- “1”“6”
Default : “1””6”
* Need to short JB3 to 3-4 closed
for enabling the backlight
brightness control.
* Apply for inverter control
voltage in range of 0~5V.
Backlight On/Off 0xe1,
“0” | “1” |
“R” | “r”
”?”
“S” | “s”
Backlight Off / Backlight On
/Status
“0” – Backlight Off
“1” – Backlight On.
“?” – Backlight On/Off Query
“S”|”s” – Backlight Status Query
Color
Monochrome
mode selection
(Output Channel
Select)
0xe2
“0” | “1” | “2” | “3” |
| “4” | “5” | “6” |
“R” | “r”|
”?”
Off/
Blue Only/
Red Only/
Green Only/
Blue Mono/
Red Mono/
GreenMono/
“0” – Off
“1” – Blue Only
“2” – Red Only
“3” – Green Only
“4” – Blue Mono
“5” – Red Mono
“6” – Green Mono
PIP Swap 0xe3 Swap Main and PIP source "0" - Fail.