Installation example
Example 1 (recommended): Installation when a stop surface of the scale and slider is
made with the bracket
Scale installation accuracy is improved when a stop surface is made. This also simplifies reinstallation of the
scale.
1. Check and adjust the scale bracket’s parallelism with respect to the machine guide, and then secure in
place.
Even when using divided brackets, adjust the parallelism over the entire bracket length as shown in the
figure.
50
0.05
MG
0.05
MG
0.05
or less
0.05 or less
Scale
bracket
Or
78
±0.3
5
±0.2
0.05
MG
78
±0.3
78
±0.3
Slider bracket
Scale bracket
Slider bracket
0.05 or less
Unit: mm
Fig. 2-5
2. Check and adjust the height and parallelism of the slider bracket, and then secure in place.
Fig. 2-6