3. Scale (SR84/85) and Connecting Cable
Steel bars are used for the scale case to achieve a high rigidity.
The magnetic shielding effect of the scale is maintained by installing steel plates inside the scale.
The scale unit and connecting cable are separated by the connector of the scale slider unit.
The cable extension direction to the right or left is selected when ordering.
All models use direct output.
3-1. Scale (SR84/85)
3-1-1. Output Signal (SR84)
When the slider is moved in the direction of the arrow, the A signal is ahead when the polarity is “positive,”
and B signal is ahead when the polarity is “negative.”
Fig. 3-1
A signal
Resolution, minimum phase difference
B signal
Reference point output signal
When the polarity is positive
Fig. 3-2
The scale movement is detected every 50 ns, and a signal is output at a phase differential time proportional
to the movement. The phase differential time varies in integer multiples of 50 ns.
An alarm signal is output, and the A/B quadrature signal becomes high impedance in the following cases.
The alarm is reset by turning the power off and then on again.
When the phase differential time of the A/B quadrature signal is 50 ns or less
When the scale signal level is less than 0.7 Vp-p
When noise or other malfunctions occur