Instruction manual

14 (E)
SR84 / SR85, CH33
Schlauchbiegeradius R: 15 mm oder mehr
Polyurethanschlauch mit 6 mm
Außendurchmesser und 4 mm
Innendurchmesser
Druckluftquelle
Filter (5 µm Filterfeinheit)
Schmiervorrichtung
Druckminderungsventil
Verteiler
Maßstab
Schlauchnippel
Innensechskantschraube (M5 6)
Nylonschlauch mit 8 mm
Außendurchmesser
4-2. Oil Lubrication
In the standard configuration, an M5 tap hole for air purging is provided in the end cap section of the scale.
If using in the following severe environments where air purge alone is not sufficient, oil mist can be injected
into the scale to reduce the effects.
The actual effects, however, will vary depending on operating conditions. Therefore, be sure to fully check
the effects before using oil lubrication.
Use in dusty area
Use in locations close to coolants
Air Tube Route and Device Configuration
Prepare the devices as shown in the figure below, and air is injected into the scale by connecting the air tubes.
Fig. 4-4
The customer must obtain the air supply unit and input/output air tube.