Specifications

10
4 ELECTRONIC CONTROL FUNCTIONS
4-1 Load Detection Function
Functions below automatically perform when overload
is generated at drilling.
Load condition of the electric drill is indicated by turning
on or blinking of LED.
LED
indication
Load condition
Green
Normal
Yellow
Normal
Red
Overload
Red
Overload
Red
(Rapid)
During automatic stop function control
Returns to normal control when load is released.
White
Overload automatic stop
Operation continues when the electric drill switch
is turned off and turned back on.
: Turned on
: Blink
Function name
LED inidcation
Description of function and countermeasure
Restart prevention function
Green
Magnet adhesion operates even when the magnet switch is turned on in a condition where the electric drill switch is
turned on or even when the battery pack is attached in a condition where the magnet switch and electric drill switch
are turned on. However, the electric drill will not operate for safety and LED blinks in green.
Turn the electric drill switch off and then turn the switch back on to continue the operation.
Warning function
Red (Rapid)
Warning function is activated in operations described below for safety.
When the magnet switch is turned on in a condition where the battery pack is attached and the battery cover is
open (condition where it is pushed toward the main body).
Make sure to draw the battery cover toward the battery pack before starting the operation. (Fig. 23)
When the battery cover is pushed toward the main body to detach the battery pack before turning the magnet
switch off
Make sure to detach the battery pack after turning the magnet switch off.
4-2 Battery Remaining Power Display Function
LED blinks three times in a color according to the
remaining power of the battery right after the magnet
switch is turned on.
LED
indication
Battery remaining power condition
Green
Approximately fully charged
Yellow
Remaining power has decreased slightly
Red
Remaining power has decreased signicantly.
Replace the battery pack to a charged battery
pack.
: Blink
Vent
Indication lamp
Part for mounting the Battery Pack
Battery Charger
Terminal
Hook
Vent
Battery Pack
Terminal cover
(Fig. 10) (Fig. 11) (Fig. 12)
4-3 Magnetic Force Control Function
Magnetic force is controlled when the electric drill is not operating with the magnet switch turned on to reduce
unnecessary electricity consumption and maintain appropriate magnetic force.
CAUTION
The magnetic force drops completely when voltage of the battery pack decreases to a certain level and may
cause the machine to fall.
Turn the magnetOFF when nished with the machine to preserve battery life.
4-4 Various Safety Functions and Error Detection Functions
LED indication is displayed as described in the table below according to the contents of safety functions and error
detection functions.