Service manual

ECR-ER-02FD cable
Fig. 3-2
4. Application specification
The following service (SRV) modes are available for the serial data
transfer of the ECR
1) Data transmit (Source side)
X: 0=SSP DATA
2) Data receive (Target)
5. Data format
A single byte image of the RAM data to be transmitted is divided into
a high order 4 bits and low order 4 bits and converted into ASCII
code. Then, the image of the memory is sent in the following format:
Memory top address: 0000H FFFFH
Top address of the memory to be transmitted in ASCII number.
Page:1F 27,00
Page of the memory to be transmitted in ASCII number.
Sum check
End code: Hex 0D
NOTE:
In order that contents of RAM memory may avoid over-riding
pages for this job, the RAM image is sent in unit of 64 bytes from
the address 0000. In other words, 128 bytes are sent at one time
on the transmit data format.
RAM DATA FORMAT
Exhibit:
Code table
HEX ASCII Character HEX ASCII Character
030 0 838 8
131 1 939 9
232 2 A41 A
333 3 B42 B
434 4 C43 C
535 5 D44 D
636 6 E45 E
737 7 F46 F
6. END record
End message: Fixed to 30303030.
End massage: Fixed to 4646.
Sum check
End code: CR (0D)
SD 2 SD
RD
CTS
RD
3
6
5
3
2
6
8
ER-02FD
75SG
RTS
4
DCD
8
DTR
20
DSR
7
1
4
ECR
CTS
SG
RTS
DCD
DTR
DSR
1FG FRAME GROUND is connected
to the shield of the cable.
25PIN D-SUB 9PIN D-SUB
SD : TRANSMITTED DATA
RD : RECEIVED DATA
DTR: DATA TERMINAL READY
DSR: DATA SET READY
RTS: REQUEST TO SEND
DCD: DATA CARRIER DETECTOR
CTS: CLEAR TO SEND
FG : FRAME GROUND
996
@/FOR
X
CA/AT
All data
SBTL
(Auto baud rate setting: ECR to ECR only)
(Baud rate
setting: #903-A)
998
CA/AT
(Auto baud rate setting: ECR to ECR only)
(Baud rate setting: #903-A)
SBTL
@/FOR
1
2
3
4
Data (128bytes)
BD
7E 83
FC
03 B6
42 44 37 45 38 33 46 43 30 33 42 36
30
3
4
303030
1
2
6 – 2