Instruction manual

83
Programming for print data sending
* Item: Selection: Entry:
A Sensing of DR signal Yes 0
No 1
B Sensing of CS signal Yes 0
No 1
C Sending of all print data Disable 0
Enable 1
Secret codes to control access to PGM1 mode, X1/Z1 mode and X2/Z2
mode
You must enter a secret code according to the following procedure before performing any PGM1-mode, X1/Z1-
mode or X2/Z2-mode operation when a secret code has been set for that specific mode operation.
Operating
Once a secret code is entered, it does not need to be entered again unless the mode switch setting
is changed and any operation is performed.
Programming
* 2630 for the PGM1 mode
2631 for the X1/Z1 mode
2632 for the X2/Z2 mode
2631
.≈
1234
;
PrintKey operation
Example
2631
2630
*
2632
.
;
Max. 4 digits
Secret code
No code (zero)
Procedure
Note
;
;
Max. 4 digits
Secret code
Procedure
263226312630
PGM 2
6220
.
;
*ABC
To program zero
Procedure
FOR THE MANAGER-2-A410/A420 02.4.20 6:49 PM Page 83