Service manual

ER-A410U/ER-A420U SPECIFICATIONS
– 3 –
4. MODE SWITCH
4-1. MODE SWITCH AND MODE KEYS
The mode switch has these settings:
5. DISPLAY
5-1. OPERATOR DISPLAY
Layout:
5-2. CUSTOMER DISPLAY
Layout:
OFF: This mode locks all register operations.
No changes may occur to register data.
OP X/Z: This setting allows cashiers to take an X or Z reports for their
sales information. This mode can also be used for displaying
the date/time and printing the employee's arrival/departure
times. This mode can be also used to toggle receipt state "ON"
and "OFF" by pressing the [RCPT] key. (To utilize this func-
tion, the register must be programmed for "OP X/Z mode avail-
able" in the PGM2 mode.)
REG: For entering sales
PGM1: To program those items that need to be changed often: e.g.,
unit prices of departments or PLUs, and percentages.
PGM2: To program all PGM1 programs and those items that do not
require frequent changes: e.g., date, time, or a variety of reg-
ister functions.
MGR: For manager’s and submanager’s entries
The manager can use this mode to make entries that are not
permitted to be made by cashiers in the REG mode.
– for example, after-transaction voiding and override entries.
X1/Z1: To take the X/Z reports for various daily totals.
X2/Z2: To take the X/Z reports for various periodic (weekly or monthly)
consolidation of totals.
REG
OP
X / Z
MGR
X
1
/Z
1
X
2
/Z
2
PG
OFF
M
1
PGM
2
MA
SM
Operative range
MA
SM
Manager key (MA)
Submanager key (SM)
OP
Operator key (OP)
Display device: LCD
Number of lines: 2 lines
Number of positions: 16 positions
Color of display: Yellow / Green
Character font: 5 x 7 dot
Character size: 4.84 (W) x 8.06 (H) mm
Display device: LED
Number of lines: 1 line
Number of positions: 7 positions
Color of display: Yellow / Green
Style: Pop up type
Character form: 7 segment + Dp
Character size: 14.2mm (H) x 7.9mm (W)