Service manual

ER-A410U/ER-A420U SPECIFICATIONS
– 4 –
Operator display
The operator display consists of a two-line dot-matrix display (16 char-
acters/line).
Cashier code or mode displayed
The mode that the key is placed in is displayed. When a cashier is
assigned, the cashier code is displayed in the REG or OP X/Z
mode. For example, “0001” is displayed when the cashier 0001 is
assigned.
• Repeat
The number of repeats is displayed, starting at "2" and increments
with each repeat. When you have registered ten times, the display
will show "0". (2 3 3......9 3 0 3 1 3 2...)
• Sentinel mark
When amounts in the drawer reaches the amount you prepro-
grammed, the sentinel mark "X" is displayed to advice you to
remove the money and take it to a safe place.
Power save mark
When the cash register goes into the power save mode, the power
save mark (decimal point) is displayed.
Stock alarm indicator
When the stock of the PLU which has been entered is zero or neg-
ative, the alarm indicator (decimal point) is displayed.
Function message display area
Item labels of Departments PLU/subdepartments and function text
you use, such as %1, (–) and CASH are displayed here. For the
details of function texts, please refer to pages 112 and 113.
When an amount entry is required, “- - - - - - -” is displayed in the
numeric entry display area with "AMOUNT". When a preset price
has been set, the price is displayed in the numeric entry display
area as the "AMOUNT".
Numeric entry display area
Numbers entered using numeric keys are displayed here.
Date and time display
The Date and time appear on the display in the OP X/Z, REG, or
MGR mode. In the REG or MGR mode, press the [#] key to display
the date and time.
Error messages
When an error occurs, the corresponding error message is displayed
in the function message display area.
Customer display (Pop-up type)
6. PRINTER
6-1. PRINTER
6-2. PAPER
6-3. LOGO STAMP
The Graphic type Logo is used
6-4. CUTTER
• Method: Manual
Function message
display area
Cashier
code or
mode name
Numeric entry
display area
Receipt OFF indicator ("_")
/
Stock alarm indicator (" ")
Repeat
/
Sentinel mark
/
Power save mark
Dept. name
/
PLU name
/
function te
xt
Price level
/
PLU level
(e.g.
P2L3)
$ ( :
Appears right below the seventh place when
the item amount is displayed at scale entry.)
Part number: PR-45M II (PR-45M compatible)
NO. of stations: 2 (Receipt and journal)
• Validation: No
• Printing system: Line thermal
No. of dots: Receipt 288 dots
• Journal 288 dots
• Dot pitch: Horizontal 0.125mm
Vertical 0.125mm
Font: font A: 12 dots x 24 dots
font B: 9 dots x 24dots
Printing capacity: Receipt max. 24 characters
Journal max. 24 characters
Character size: 1.5mm (W) x 3.0mm (H) at 12 x 24 dots
1.125mm (W) x 3.0mm (H) at 9 x 24 dots
Print pitch: Column distance 1.5mm at 12 dots
1.125mm at 9 dots
Row distance 3.75mm
• Print speed: Approximate 50mm/s
• Paper feed speed:
(Manual feed)
Approximate 40mm/s
Reliability: Mechanism MCBF 5 million lines
Paper end sensor: Optional (Receipt and journal)
• Cutter: Manual
• Near end sensor: No
Note :
The PR-45MII has a minor change over the model of the PR-45M.
This printer does not include the gear cover (GCOVH7146BHZZ)
which is for the PR-45M only.
• Paper roll dimension: 44.5 m 0.5mm in width
Max. 83mm in diameter
• Paper quality: (Journal/Receipt)
High-quality paper
paper thickness: 0.06 to 0.08mm