Service manual

UX-8TH/UX-40TH
GQ-5TH/FO-50TH
1 Auto gain control(MODEM) Enable Disable 1
2 End Buzzer Yes No 1
3 Disconnect the line when DIS is received in No Yes 1
RX mode
4 Equalizer freeze control(MODEM) On Off 0
5 Equalizer freeze control 7200 bps only No Yes 0
6 CNG transmission in manual TX mode Yes No 1
7 Initial compression scheme for sharp fax in MR mode H2 mode 0
TX mode
8 Modem speed automatic down when RX Yes No 0
level is under -40dBm
EOL detect timer 5 seconds 13 seconds 20 seconds 25 seconds
1 No. 1001 10
2 No. 2010 11
3 Reserved 0
4 Reserved 0
5 Reserved 0
6 Reserved 0
7 Reserved 0
8 Reserved 0
1 Hold key Enable Disable 1
2 Auto dial fax transmission by REDIAL key Yes No 0
3 Reserved 0
4 Recall interval Binary input 0
5 (0~15.5min setting by 0.5min step) No. = 16 8 4 2 1 1
6 4 5 6 7 8 0
7 0 1 0 1 0 1
8 0
1 Recall times(0~15times setting) Binary input 0
2 No. = 8 4 2 1 0
3 1 2 3 4 1
4 0 0 1 0 0
5 Dial tone detection(Before auto dial) No Yes 1
6 Reserved 0
7 Busy tone detection(After auto dial) No Yes 1
8 Busy tone detection pulse number 4 pulses 2 pulses 0
(After auto dial)
Waiting time after dialing
45 seconds 55 seconds 90 seconds 140 seconds
1 No. 1001 10
2 No. 2010 10
3 Reserved 0
4 Reserved 0
5 Reserved 0
6 Reserved 0
7 Reserved 0
8 Reserved 0
1 Dial pausing(sec/pause) 4 sec 2 sec 0
2 Dial mode Tone Pulse 1 OPTION
3 Pulse Tone change function by key Enable Disable 1
4 Dial pulse make/break ratio(%) 40/60 33/67 1
Auto dial mode Delay timer of before line
0 second 1.5 seconds 3.0 seconds 4.5 seconds
5 connect No. 5 0 0 1 1 1
6No. 601010
7 Reserved 0
8 Reserved 0
SW
NO.
DATA
NO.
ITEM
Switch setting and function
1
0
SW
l
B3
SW
l
B2
SW
l
A7
SW
l
A6
2 – 6
SW
l
B1
SW
l
B4
Remarks
Initial
setting