Service manual

FO-IS125N
2 – 10
2.12. MEMORY SET MODE
It is possible to read or write the memory contents.
When 8 digits of physical address are entered, the data of that address
is displayed.
When 2 digits of data are entered after entering 8 digits of address and
a key is pressed, the contents can be rewritten.
Rewriting is enabled only in the range of addresses 00000000 to
007FFFFF.
If the memory is rewritten, the machine may malfunction.
Press the [STOP] key on the address entry screen to exit the mode.
2.13. CIS ADJUST
In this mode, the position of Scanner motor is moved from the home
position up to the specified value. And document reading lamp is
turned on.
Press the [STOP] key to exit the mode.
2.14. SHARP CHART MODE
SHARP CHART is printed continuously.
Press the [STOP] key for interruption.
2.15. 5% CHART
5% CHART is printed continuously.
Press the [STOP] key for interruption.
2.16. ASF AGING
The recording paper is fed continuously.
Press the [STOP] key for interruption.
2.17. PASSCODE LIST
Used to print the passcode (SECURE FAX, etc.).
2.18. LIFE SET MODE
A mode for checking or setting the life value of each operation. Enter
the count value (10-digit number) of the set life using the numeric key-
pad.
This counter shows the printer usage status (number of printed sheets
after starting use, etc.). The counter cannot be reset by normal mem-
ory clear. Therefore, if the memory contents on the control PWB are
destroyed when repairing it, this counter setting must be cleared in
addition to normal memory clear.
Press the [STOP] key to exit the mode.
2.19. LIFE CLR MODE
A mode for clearing the life value.
DIAG MODE
MEMORY SET MODE
MEMORY SET MODE
xxxxxxxx= [ ]
[START/MEMORY] key
Address entry screen
Entry of memory address (8 digits)
MEMORY SET MODE
1234ABCD=4C [L]
Hex
number
Character
code
Change of memory contents: 2-digit entry in hex number
Move down the address of the referenced memory by one: [<] or [UP] key
Move up the address of the referenced memory by one: [>] or [DOWN] key
Dump list print: [COPY/HELP] key
Back to the address entry screen: [STOP] key
The contents of the memory are displayed
in hex number and character code.
DIAG MODE
CIS ADJUST
[START] key
[START] key
The motor will move to the specified position and the reading lamp is lit on.
CIS ADJUST MODE
Start by pressing the
[START] key
DIAG MODE
SHARP CHART MODE
SHARP CHART AGING
TOTAL PAGE 1
Start by pressing the
[START] key
DIAG MODE
5% CHART
5% CHART AGING
TOTAL PAGE 1
Start by pressing the
[START] key
DIAG MODE
ASF AGING
ASF AGING
Start by pressing
the [START] key
PRINTING
DIAG MODE
PASSCODE LIST
[START] Key
LIFE=0000000231
LIFE=0000000231
LIFE=0000000099
DOT COUNT=1234567890
[START] Key
SCAN
PRINT
DRUM
TONER PAGE
TONER DOTCOUNT
[START] Key
[START] Key
[START] Key
[START] Key
[DOWN] Key
[DOWN] Key
[DOWN] Key
[DOWN] Key
LIFE=0000000231
JAM=0000000001
SCAN JAM
[START] Key
[DOWN] Key
DIAG MODE
LIFE MODE
[START] Key
CLEARED
CLEARED
CLEARED
[START] Key
ALL
PRINT
DRUM
TONER
[START] Key
[START] Key
[START] Key
[DOWN] Key
[DOWN] Key
[DOWN] Key
CLEARED
CLEARED
SCAN
[START] Key
[DOWN] Key
DIAG MODE
LIFE CLR MODE
When clearing "TONER",
"TONER PAGE" and
"TONER DOT COUNT" are
also cleared.