Service manual

FO-IS125N
2 – 12
4. Soft switch description
4.1. Soft switch
SW
NO.
DATA
NO.
ITEM
Switch setting and function
Initial
setting
Remarks
10
SW
1
1
2
Receive mode AUTO MANU.
0
0
RECEPTION
key
No.1 0 0
No.2 0 1
3Reserved 1
4Reserved 0
5Reserved 0
6Reserved 0
7 Sort copy function Yes (Sort) No 0 OPTION
8Reserved 0
SW
2
1 Forced 4800BPS reception Yes No 0
2
3
CED tone signal interval 75ms 500ms 750ms 1000ms
0
0
No.20011
No.30101
4Reserved 0
5Reserved 0
6Reserved 0
7 Footer print Yes No 0
8Reserved 0
SW
3
1Reserved 0
2 CSI transmission Not transmitted Transmitted 0
3 Action when RTN is received No communication error Communication error 0
4Reserved 1
5 Pulse format N+1 N 0
6 DIS receive acknowledgement dur-
ing G3 transmission
Twice NSF: Once
DIS: Twice
0
7 Non-modulation carrier for V29
transmission mode
Yes No 0
8 Default file format for network scan PDF TIFF 0 e-mail setting
SW
4
1 Protocol monitor Yes No 0
2 Line monitor Yes No 0
3Reserved 0
4 Sender's information transmit No Yes 0
5Reserved 0
6Reserved 0
7 H2 mode No Yes 0
8 ECM mode No Yes 0
SW
5
1 ECM MMR mode No Yes 0
2
3
4
5
Signal transmission level 1
1
0
1
6Reserved 0
7Reserved 1
8 Key tone Off On 0 OPTION
Binary input
No. = 8 4 2 1
2345(DataNo.)
EX1101
eg. -13dBm