Service manual

FO-IS125N
2 – 13
SW
NO.
DATA
NO.
ITEM
Switch setting and function
Initial
setting
Remarks
10
SW
6
1
2
3
4
Recall interval (FAX) 0
1
0
1
Setting:
N = 1 to 9
5
6
7
8
Recall times (FAX) 0
0
1
1
Setting:
N = 1 to 9
SW
7
1Reserved 0
2Reserved 0
3 Dial mode Pulse Tone 0
4Reserved 1
5Reserved 0
6 CNG detection Yes No 1
7 Number of CNG detection 3 pulses 2 pulses 0
8 Time format 24hours 12hours-AM/PM 0
SW
8
1
2
3
4
Modem speed(Except V.34 mode) No. 1 No.2 No. 3 No. 4
1
0
0
0
V.29 9600bps 0 0 0 1
V.29 7200bps 0 0 1 1
V.27ter 4800bps 0 0 1 0
V.27ter 2400bps 0 0 0 0
5Reserved 0
6Reserved 0
7Reserved 0
8Reserved 0
SW
9
1Reserved 1
2Reserved 1
3Reserved 0
4Reserved 0
5Reserved 1
6 Polling key setting Yes No 0 OPTION
7 Polling security Yes No 1 ENTRY mode
8 Date format Month-Day-Year Day-Month-Year 1
SW
10
1Reserved 0
2Reserved 0
3Reserved 0
4Reserved 0
5Reserved 0
6
7
8
Communication results printout No. 6 No. 7 No. 8
0
0
1
OPTION
Error Only 0 0 1
Error/Memory 0 0 0
Transmission 0 1 0
Not Printed 1 0 0
Every Time 1 1 0
SW
11
1Reserved 0
2 Activate receive fax to e-mail On Off 0 Fax to e-mail/
Folder
3 Activate secure receive On Off 0 SECURITY
4Reserved 0
5Reserved 0
6Call restriction 0 SECURITY
7Reserved 0
8Reserved 0
Binary input
No. = 8 4 2 1
1234(DataNo.)
EX0101
eg. 3 minutes
Binary input
No. = 8 4 2 1
5678(DataNo.)
EX0011
eg. 5 times