Service manual

FO-IS125N
2 – 15
SW
NO.
DATA
NO.
ITEM
Switch setting and function
Initial
setting
Remarks
10
SW
17
1Reserved 1
2Reserved 0
3Reserved 0
4Reserved 0
5Reserved 0
6Reserved 0
7 Automatic reduce of receive 100% Auto 0 OPTION
8Reserved 0
SW
18
1Reserved 1
2Reserved 0
3Reserved 1
4Reserved 0
5Reserved 0
6Reserved 0
7Reserved 0
8Reserved 0
SW
19
1Reserved 0
2Reserved 0
3Reserved 0
4Reserved 0
5Reserved 0
6Reserved 1
7Reserved 0
8 Send hold Yes No 0 SECURITY
SW
20
1
2
3
4
5
DTMF output level (High)
0
1
1
0
1
6Reserved 0
7Reserved 0
8Reserved 0
SW
21
1
2
3
4
5
DTMF output level (Low)
1
0
0
0
1
6Reserved 0
7Reserved 0
8Reserved 0
SW
22
1
2
3
Dial tone detection frequency No. 1 No. 2 No. 3
0
0
1
280 - 520Hz 0 0 0
380 - 500Hz 0 0 1
300 - 600Hz 1 0 0
Reserved 010
Reserved 011
Reserved 101
Reserved 110
Reserved 111
4
5
Busy tone detection frequency No. 4 No. 5
0
0
520 - 640Hz 0 0
300 - 600Hz 0 1
380 - 500Hz 1 0
520 - 640Hz 1 1
6Reserved 0
7Reserved 0
8Reserved 0
Binary input
No.= 168421
1 2 3 4 5 (Data No.)
EX0 1101
eg. Signal transmission level is set to -10dBm
Binary input
No.= 168421
1 2 3 4 5 (Data No.)
EX1 0001
eg. Signal transmission level is set to -10dBm