Service manual

FO-IS125N
2 – 34
SW
NO.
DATA
NO.
ITEM
Switch setting and function
Initial
setting
Remarks
10
SW
145
1
2
3
4
Detect time of LAN link on
0
0
0
0
1 - 15 seconds
5
6
7
8
Detect time of LAN link off
0
0
0
0
1 - 15 seconds
SW
146
1 Reserved 0
2
3
Default resolution for network scan Stan-
dard
Fine S-Fine
0
1
No. 2001
No. 3010
4 Reserved 0
5 Reserved 0
6 Reserved 0
7 Reserved 0
8 Reserved 0
SW
147
1 Reserved 0
2 Reserved 0
3 Reserved 0
4 Reserved 0
5 Reserved 0
6 Reserved 0
7 Reserved 0
8 Reserved 0
SW
148
1
2
3
4
DST start time-Month (1-12)
0
0
1
1
OPTION
5
6
7
8
DST start time-Week 1st
week
2st
week
3st
week
4st
week
Last
week
0
0
1
0
OPTION
No. 500000
No. 600011
No. 701100
No. 810101
Binary input
No. = 8 4 2 1
1234(DataNo.)
EX0100=4seconds
Note:"0000"=1UGEQPF
Binary input
No. = 8 4 2 1
5678(DataNo.)
EX0100=4seconds
Note:"0000"=1UGEQPF
Binary input
No. = 8 4 2 1
1234(DataNo.)
EX0011
Set value: 1~12