Service manual

FO-IS125N
2 – 52
SW7 No. 7 Number of CNG detection
Used for detection of CNG in 2 or 3 pulses.
SW7 No. 8 Time format
When this switch is set to "0", time is displayed in 12-hour system.
When set to "1", 24-hour system.
SW8 No. 1 ~ No. 4 Modem Speed (Except V.34 mode)
Used to determine the initial modem speed. The default is
14400BPS(V.17). It may be necessary to program it to a slower speed
when frequent line fallback is encountered, in order to save the time
required for the fallback procedure.
SW8 No. 5 ~ No. 8 Reserved
SW9 No. 1 ~ No. 5 Reserved
SW-9 No. 6 Polling key setting
Used to specify whether to enable or disable the polling key.
SW-9 No. 7 Polling security
Used to specify whether to allow the polling request from the other
party's machine without conditions or to allow only the request from
the authorized other party's machine.
SW9 No. 8 Date format
Used to select date display/print formats.
0: DAY-Month-Year
1: Month-Day-Year
SW10 No. 1 ~ No. 5 Reserved
SW10 No. 6 ~ No. 8 Communication results printout
It is possible to obtain communication results after each transaction.
Normally, the switch is set (No. 6: 0, No. 7: 0, No. 8: 1) so that the
communication result is produced only a communication error is
encountered. If No. 6 was set to 1, No. 7 was set to 1 and No. 8 was
set to 0, the communication result will be produced every time a com-
munication is done, even if the communication was successful. If No. 6
was set to 0, No. 7 to 1 and No. 8 to 0, the communication result will
be produced every transmission. Setting No. 6 to 1 No. 7 to 0 and No.
8 to 0 will disable this function. No transaction report will be printed. If
No. 6 was set to 0, No. 7 to 0 and No. 8 to 0, the communication result
is produced only after a memory transmission or when a communica-
tion error is encountered.
SW11 No. 1 Reserved
SW11 No. 2 Activate receive fax to e-mail
The receive fax to e-mail function ON/OFF is set.
SW11 No. 3 Activate secure receive
The Secure receive function ON/OFF is set.
SW11 No. 4, No. 5 Reserved
SW11 No. 6 Call Restriction
Used to set the call restriction function to ON or OFF.
SW11 No. 7, No.8 Reserved
SW12 No. 1, No. 2 Reserved
SW12 No. 3, No. 4 EOL (End of Line) detection timer
Used to make a choice of whether to use the 25-second or 13-second
timer for detection of End of line This is effective to override communi-
cation failures with some facsimile models that have longer End of line
detection.
SW12 No. 5 ~ No. 8 Reserved
SW13 No. 1 ~ No. 3 DTMF ON time
Used to set the ON time of the DTMF signal when setting the tone dial.
SW13 No. 4 ~ No. 6 DTMF OFF time
Used to set the OFF time of the DTMF signal when setting the tone
dial.
SW13 No. 7 Make/Bread ratio in DP
Used to set the pulse make/break ratio when setting the pulse dial.
SW13 No. 8 Reserved
SW14 No. 1 ~ No. 3 Inter digit pause time
Used to set the pause time between the dial data when setting the
pulse dial.
SW14 No. 4 Change to PB from DP by " "key
Used to set the function for switching to the tone dial by entering " "
to ON or OFF when setting the pulse dial.
SW14 No. 5 ~ No. 8 Reserved
SW15 No. 1 ~ No. 8 Reserved
SW16 No. 1 ~ No. 8 Reserved
SW17 No. 1 ~ No. 6 Reserved
SW17 No. 7 Automatic reduce of receive
If set to 1, it is reduced automatically when receiving.
SW18 No. 1 ~ No. 8 Reserved
SW19 No. 1 ~ No. 7 Reserved
SW19 No. 8 Send hold
Set the send hold function to ON or OFF.
SW20 No. 1 ~ No. 5 DTMF output level (High)
To set the level to output high group DTMF signals. -15 to 0 dBm
(0.5dBm unit)
SW20 No. 6 ~ No. 8 Reserved
SW21 No. 1 ~ No. 5 DTMF output level (Low)
To set the level to output low group DTMF signals. -15 to 0 dBm
(0.5dBm unit)
SW21 No. 6 ~ No. 8 Reserved
SW22 No. 1 ~ No. 3 Dial tone detection frequency
To select frequency range of signals to be detected as Dial Tone.