[3] Troubleshooting
Refer to the following actions to troubleshoot any of the problems
mentioned in 1-4.
[1] A communication error occurs.
[2] Image distortion produced.
[3] Unable to do overseas communication.
[4] Communication speed slow due to FALLBACK.
In crease the transmission level SOFT SWITCH SW5-2, 3, 4, 5.
May be used in case [1] [2] [3].
Decrease the transmission level SOFT SWITCH SW5-2, 3, 4, 5.
May be used in case [3].
Apply line equalization SOFT SWITCH SW5-2, 3, 4, 5.
May be used in case [1] [2] [3] [4].
Slow down the transmission speed SOFT SWITCH SW5-2, 3, 4, 5.
May be used in case [2] [3].
Replace the LIU PWB.
May be used in all cases.
Replace the control PWB.
May be used in all cases.
If transmission problems still exist on the machine, use the follow-
ing format and check the related matters.
TO: ATT: Ref.No. :
CC: ATT: Date :
FM: Dept :
Sign :
* Please complete this report before calling the "TAC" hotline if problem still occurs.
***** Facsimile communication problem ***** Ref.No.:
Date:From: Mr. Fax Tel No.:
Our customer Name Tel N o .
Address Fax No.
Contact person Model name
Other party Name Tel N o .
Address Fax No.
Contact person Model name
Problem mode Line: Domestic / international Model: G3 Phase: A, B, C, D.
Reception / Transmission
Automatic reception / Manual reception
Automatic dialing / Manual dialing / Others
Frequency: % ROM version:
Confirmation
item
Please mark problem with an X.
No problem is: 0.
A1 A2 B1 B2 C1 C2 D1 D2 E1 E2
Transmission level setting is ( ) dB at our
customer
Transmission level ( ) dBm
Reception level ( ) dBm
By level meter at B1 and B2
Comment
**** Please attach the G3 data and activity report on problem. ****
Countermeasure
Our customer
Our service
A1 A2
C1 D2
B1
B2
E1
E2
C2 D1
Other party
Other
p
art
y
's service