R AIR PURIFIER OPERATION MANUAL Floor / Tabletop type *Plasmacluster is a trademark of Sharp Corporation.
ENGLISH FEATURES The unit controls the ratio of negative ions and positive ions depending on the condition of the room. • Clean Mode CONTENTS Approximately the same numbers of positive and negative ions are discharged. This mode is effective for reducing some airborne mold. SAFETY PRECAUTIONS ........................ E-2 • RISK OF ELECTRIC SHOCK ...................... E-2 • Ion Control Mode Plenty of negative ions exist in natural surroundings such as waterfalls or forests.
SAFETY PRECAUTIONS RISK OF ELECTRIC SHOCK • These servicing instructions are for use by qualified personnel only. To reduce the risk of electric shock, do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so. • Do not use the unit if the power cord or plug is damaged or the connection to the wall outlet is loose. Electrical shock, short circuit and/or fire may occur as a result.
• Do not block the intake and air outlet. • Do not use the unit near or on hot objects, such as a stove. Also, do not use the unit where it may come into contact with steam. • Do not use the unit on its side. Deformation, malfunction and/or overheating of the motor may occur as a result. • Do not install when there is generation of oily residue, such as in a kitchen. • Do not use detergent when cleaning the unit. The unit surface may become damaged or cracked.
PART NAMES AUTO Operation Indicator Light MAIN UNIT DISPLAY OFF Timer Display Indicator Lights (set using remote control) Filter Indicator Light If the Filter Indicator Light is lit, it indicates filter replacement period. PLASMACLUSTER INDICATOR LIGHT Plasmacluster ion operation is selected using the remote control.
Pollen Mode Indicator Light CLEAN-SIGN LIGHT The color changes according to the air condition. Clean (Green) Slightly Impure (Orange) Very Impure (Red) CLEAN-SIGN CLEAN-SIGN CLEAN-SIGN Remote Control Receiver • The sensors display a CLEAN-SIGN depending on relative changes to the environment from the time the power plug is inserted into the wall outlet and thereafter.
PART NAMES BACK Purified Air Louver Handle • The purified air discharge can be changed to the directions indicated by the arrows as desired.
PREPARATION INSERTING BATTERIES IN THE REMOTE CONTROL 1 Remove the back cover 2 Insert batteries Insert batteries with shown below. and Close the back cover Battery Information • The batteries for this remote control are for initial use only . Change the batteries when necessary. • Incorrect usage of the batteries may cause battery fluid leakage and/or damage. Take care of the following when handling: • When replacing the batteries, replace both batteries with new ones of the same type.
PREPARATION • Be sure to remove the power plug from the wall outlet. Be sure to remove the power plug from the wall outlet. FILTER INSTALLATION To maintain the quality of the filters, they are placed in the main unit within plastic bags. Be sure to remove the filters from the plastic bags before using the unit. 1 Filter Removal 1 Place the unit facing up. Lay the unit on a flat surface such as a table, making sure not to pinch the power cord on the rear of the unit.
2 Filter Installation Tabs the HEPA Filter is removed 1 After from the plastic bag, place it within the Filter Frame with the tabs facing up. Filter Frame Ensure that the filter is installed correctly. Do not install the filter backwards or the unit will not operate properly. removing the Active Car2 After bon Filter from the plastic bag, Active Carbon Filter place it within the Filter Frame on top of the HEPA Filter. HEPA Filter (See the diagram to the right.
OPERATION For the first 30 seconds after the power plug is inserted into the wall outlet, the unit will check the condition of the air. If operation is set to ON during this time, the CLEAN-SIGN LIGHT will alternately flash green, orange and red. MAIN UNIT OPERATION Main Unit Controls • AUTO • SILENT • MEDIUM • HIGH • MAX • POLLEN Plasmacluster Indicator Light Plasmacluster MODE / The unit will start operating when the MODE / Button Button is pressed. The unit will begin operating in the AUTO Mode.
REMOTE CONTROL OPERATION • When you press the POWER ON/OFF Button, a short beep will sound and operation will start. As the initial operation mode, it automatically goes to the AUTO (Fan level) and AUTO Plasmacluster ion Mode. • To stop operation, press the POWER ON/OFF Button again. A long beep will sound and operation will stop. Transmitter POWER ON/OFF Button Used to start AUTO operation of the unit. A short beep will signal that the unit is on and a long beep means that the unit is off.
CARE AND MAINTENANCE (To maintain optimum performance of this product, please clean the unit including its sensors and filters periodically.) When cleaning the unit, be sure to unplug the power cord, and never handle the plug with wet hands. Electrical shock and/or bodily injury may occur as a result. MAIN UNIT DUST SENSOR ODOR SENSOR To prevent dirt or stains on the main unit, clean as often as necessary. If stains are allowed to remain, they may become hard to clean.
FILTER REPLACEMENT GUIDELINES The filter replacement period is indicated by the Filter Indicator Light. (The Indicator light will light up in about 5 years, when using the unit for 12 hours daily.) • The operation hours are saved in memory even when removing the power plug for transportation to another room, etc. The Filter Indicator Light is to be used only as a guide. If dust or odors cannot be removed easily, replace the filters.
OPERATION GUIDE ODOR SENSOR GUIDELINES • The Odor Sensor responds to cigarette and pet odors, as well as other scents such as Insecticide, cosmetics, spray, alcohol, or sudden changes in temperature or humidity. • When the unit is in Auto Mode and room is in a closed environment the sensor will respond to some odors by increasing the air flow. If you do not desire increased air flow, please adjust the sensitivity of the sensor.
TROUBLESHOOTING SYMPTOM REMEDY (not a malfunction) The Remote Control does not work • Have the batteries been depleted? • Are the batteries inserted correctly? • Is a fluorescent lighting in the room flickering due to service life? (Refer to E-3,E-7) Odors and smoke are not removed • Are the filters heavily soiled? (Refer to E-13) The CLEAN-SIGN Light lights green even when the air is impure • Is the opening of the odor sensor blocked or the sensor filter clogged? (Refer to E-12) • The air could be i
SPECIFICATIONS Model Power supply Fan Level Adjustment Fan Level Operation Rated Power Fan Level FU-60SE-P 230V / 60Hz Max 53 W 360 m3/hour Medium 6W 95 m3/hour Silent 4W 43 m3/hour ~46m2 * Applicable Floor Surface Cord Length Dimensions High 19 W 218 m3/hour 2.5m 415mm(W)x238mm(D)x572mm(H) Weight 9.3kg * The applicable floor surface area is appropriate for operating the unit at Max fan level.