R FU-Y30J-W AIR PURIFIER OPERATION MANUAL ENGLISH *Plasmacluster is a trademark of Sharp Corporation. Free standing type FU-Y30J-W.indd 1 09.10.
Please read before operating your new Air Purifier Some odour ingredients absorbed by the filter may become separated and may be discharged through the air outlet and result in additional odour. Depending on the usage environment, especially when the product is used in a condition significantly more severe than household use, this odour may become strong in a shorter period than expected. In this case we recommend purchasing the optional replacement filter.
ENGLISH "Plasmacluster" technology Plasmacluster technology uses plasma discharge to produce and release the same positive and negative ions as those found in nature ("Plasmacluster ions"). This is a unique air cleaning technology of the SHARP CORPORATION for breaking down and inactivating such potential allergens as the faecal matter or corpses of aerial mites*1, viruses* 2 and mould and bacteria* 3 suspended in the air, and has been substantiated by third-party organisations both in Japan and overseas.
IMPORTANT SAFETY INSTRUCTIONS When using electrical appliances, basic safety precautions should be followed, including the following: WARNING - To reduce the risk of electrical shock, fire or injury to persons: • Read all instructions before using the unit. • Use only a 220-240 volt outlet. • Do not use the unit if the power cord or plug is damaged or the connection to the wall outlet is loosened. • Periodically remove dust from the power plug.
IMPORTANT SAFETY INSTRUCTIONS CAUTIONS CONCERNING OPERATION ENGLISH • Do not block the air intake and/or outlet. • Do not use the unit near or on hot objects, such as stoves or heaters or where it may come into contact with steam. • Do not lay the unit down when turned on. • Always hold the handle on both sides of the unit when moving it. Holding the back panel when carrying may cause it to detach, thus dropping the unit and resulting in personal injury. • Do not operate the unit without the filter.
PART NAMES MAIN UNIT DISPLAY POWER ON/OFF Button Plasmacluster Ion ON/OFF Button MODE Button Fan Speed Indicator Lights Plasmacluster Ion ON/OFF Indicator Light ILLUSTRATIVE DIAGRAM Handle Main Unit E-4 FU-Y30J-W.indd 6 09.10.
INCLUDED • Operation manual BACK Handle Filter (Dust Collection / Deodorising Filter) ENGLISH Tab Date Label Air Outlet Back Panel Air Inlet Power Cord Plug (Shape of plug depends on country.) E-5 FU-Y30J-W.indd 7 09.10.
PREPARATION Be sure to remove the power plug from the wall outlet. FILTER INSTALLATION To maintain the quality of the filter, they are installed in the main unit and packed in plastic bag. Be sure to remove the filter from the plastic bag before using the unit. 1 Tab Remove the filter 1 Remove the Back Panel. Pull the tab at the top of the Back Panel. the Filter from the 2 Remove plastic bag. 2 Intall the filter 1 Place the Filter within the main unit.
2 Replace the Back Panel to the main unit. 3 Fill in the usage start date on the Date Label. ENGLISH Push until it clicks into place. Use the date as a guide for the filter replacement schedule. Date Label E-7 FU-Y30J-W.indd 9 09.10.
OPERATION MAIN UNIT OPERATION MODE Button Plasmacluster Ion ON/OFF Button Fan Speed Indicator Lights Plasmacluster Indicator Light POWER ON/OFF Button Power ON/OFF Button • Press to start operation (short beep) and stop operation (long beep) • Plasmacluster Indicator Light and Fan Speed Indicator Light turn on/off. • Unless the power cord has been unplugged, the operations starts in the previous mode it was operated in. MODE Button • Press the MODE Button to select the desired fan speed.
CARE AND MAINTENANCE To maintain optimum performance of this air purifier, please clean the unit including the filter periodically. When cleaning the unit, be sure to unplug the power cord, and never handle the plug with wet hands. Electrical shock and/or bodily injury may occur as a result. BACK PANEL Care Cycle Whenever dust accumulates on the unit or every 2 weeks Gently remove dust from the back panel, using a vacuum cleaner attachment or similar tool.
CARE AND MAINTENANCE FILTER REPLACEMENT GUIDELINES Filter life vary depending on the room environment, usage, and location of the unit. If dust or odour persists, replace the filter. (Refer to “Please read before operating your new Air Purifier”) Guide for filter replacement timing • The following filter life and replacement period is based on the condition of smoking 5 cigarettes per day and the dust collection/deodorisation power is reduced by half compared with that of new filter.
TROUBLESHOOTING Before calling for repair, please review the list below, since the problem may not be a unit malfunction. SYMPTOM REMEDY (not a malfunction) Odours and smoke are not removed. • Clean or replace the filter if they appear to be heavily soiled. (Refer to E-9,E-10) A clicking or ticking sound is heard from the unit. • Clicking or ticking sounds may be audible when the unit is generating ions. • Check to see if the filter are heavily soiled. Replace the filter.
SPECIFICATIONS Model Power supply Fan Speed Adjustment Fan Rated Power Speed Operation Fan Speed Recommended Room Size High density Plasmacluster ion recommended room size Cord Length Dimensions Weight FU-Y30J-W 220-240V 50/60Hz MAX 49W 180m3/hour MED 32W 120m3/hour LOW 23W 60m3/hour ~21m2 *1 ~13m2 *2 2.0m 356mm(W)x180mm(D)x510mm(H) 5.0kg *1 Size of a room which is appropriate for operating the unit at maximum fan speed.
ENGLISH Memo FU-Y30J-W.indd 15 09.10.
SHARP CORPORATION OF AUSTRALIA PTY.LTD. A. B. N. 40 003 039 405 1 HUNTINGWOOD DRIVE, HUNTINGWOOD, N.S.W. 2148 P.O.BOX 6827, BLACKTOWN. N.S.W. 2148 SHARP CORPORATION OF NEW ZEALAND LIMITED 59 HUGO JOHNSTON DRIVE PENROSE, AUCKLAND Printed in China TINS-A351KKRZ 09K FU-Y30J-W.indd 16 1 09.10.