Datasheet
DG-
MODEL No. Page
GW5
9/14
□□C15L00
4. Reliability
The reliability of products shall be satisfied with items listed below.
4-1. Test items and test conditions Confidence level: 90%
No. Test items
Test conditions
Samples Defective LTPD
n C (%)
1 Temperature -40 ℃(30 min)~+100 ℃(30 min), 30 times
cycle
11 0 20
2
High temp and high Ta*=+60℃, RH=90%, t=1000h
humidity storage
11 0 20
3 High temperature Ta*= +100℃, t=1000h
storage
11 0 20
4 Low temperature Ta*= -40 ℃, t=1000h
storage
11 0 20
5 Operating test Tc=60 ℃,IF=400mA, t=1000h
11 0 20
6 Mechanical shock 15000 m/s
2
, 0.5 ms
test ±X・±Y・±Z direction, 3 times
5
0
50
7
Variable frequency 200 m/s
2
, 100~2 000~100 Hz / sweep for 4 min.
vibration X・Y・Z direction, 4 times
5
0
50
4-2. Failure judgment criteria (*1 , 4 - 1. No.1~7) (Ta*=25℃)
No. Parameter Symbol Condition
Failure judgment criteria (*2)
1 Forward voltage
V
F
IF=360mA
V
F
> U.S.L × 1.1
2 Luminous flux Φ IF=360mA
Φ<Initial value × 0.5,Φ>Initial value × 2.0
*1 : Measuring condition is accordance with this specification.
*2 : U.S.L. is shown by Upper Specification Limit.
※ This specification is reference.