2. Check the distance from the fluorescent lamp by using an illuminance meter.
In the proper position for black defect correction, illuminance is between 8,000 and 10,000 lux.
Figure 81
3. Hold the handset in the proper position.
Figure 82
4. Click the “Black defect correction” button.
The following message is displayed.
Figure 83
5. Click the “Yes” button. Communication starts.
Figure 84