NMEA2
AT44 Active Tee
SimNet
CX34
Tee Joiner
NET
Installation 1 - 18 CX34/44/54 NavStation
1.8.4 Interface connection
The 34, 44 and 54 series feature three possibilities for interconnection and
data sharing:
1. SimNet, which is recommended for control and data sharing
between Simrad SimNet products.
2. NMEA2000, SimNet products will interface and share data with
NMEA2000 based products.
3. NMEA0183, which has been the common standard for marine elec-
tronics. Interface connections are made to the receptacle on CX34
marked “NMEA, or on CX44/54 marked “NMEA1” or “NMEA2”
on the rear of the cabinet – turn the plugs coupling ring clockwise
until it stops.
) The unit must be turned off while connecting/disconnecting the
interface cable.
SimNet is a high-speed control and data network designed to integrate SimNet
products into a complete system. Ready-made cables with small plugs makes
it easy to run cables. Only 10 mm (3/8”) holes are required through panels and
bulkheads. The SimNet accessory program contains the necessary items to
make a successful installation, see section 1.14 Specifications.
Plug and Play - once all products are connected and power is switched on, the
entire network system will be set up automatically and will ensure optimum
performance.
SimNet interface connection for CX34 is made directly to the receptacle
marked NET on the rear of the cabinet. Use a Tee Joiner to make a drop
connection from the SimNet system to the NET receptacle.
SimNet connection to CX44 and CX54 is made via AT44, which is a special
SimNet to NMEA converter with a plug for the NMEA2 receptacle and two
sockets for SimNet.