Installation manual

Precaution: Do not open the equipment, only authorized Simrad technicians
are qualified to do so. If the glass in the screen breaks, be carefull not to cut
yourself on the sharp edges of the glass pieces. There is high voltage present
inside the scanner which may also be present even after power is turned off.
) The lifetime of the internal battery is minimum 5 years. If not exchanged
before it goes flat, all data in the unit’s memory will be lost. We strongly
recommend that you frequently store your data on a Simrad DataCard. For
exchange of battery, call your local Simrad workshop.
Power source, fuse and power cable: Check that the DC power supplied to
the unit is within the range of 10 to 32 volts. Note that the appropriate fuse
must be employed (see fuse ratings in the Specifications). Ensure that the
power cord is firmly attached.
Grounding: To reduce electrical interference and risk of electrical shock,
properly ground the NavStation to the ships ground using the ground screw
at the rear of the unit. Good grounding should also be exercised for connected
equipment.
Cleaning: Do not use any kind of strong solvents e.g. spirit, alcohol, gasoline
or oils.
Software: The software version of the main unit (see start-up display) should
always be informed in a service situation, or when ordering a Dual Station.