Installation manual

Rotation Radius
R550 (3 ft. ant.)
R700 (4 ft. ant.)
R985 (6 ft. ant.)
IMPORTANT
Front
CX34/44/54-series Installation 1-37
Drilling template for RB716A, RB717A, RB718A.
The bolts included with your radar
equipment will suffice for mount
base thickness of 9 to 14 mm (0.35 to
0.55 in.). If the mount base is thicker
or thinner than this, prepare bolts as
listed on page 1-31.
Silicone should be applied to secure
the bolts. Do not use locking putty, as
it may damage the radome.
Remove the protective cap covering
the rotary coupler on the top of the
scanner. Match the antenna radiation
direction to direction of the arrow on
the rotation base and fix the antenna
in position using the four M8 acces-
sory bolts.
1.13.3 Connecting cables (length of cables – see 1.14 Specifications)
Run the cables by following these instructions:
• Do not bind the cable for the radar collectively with cables of other equip-
ment (especially the power supply cable).
• Run the cable along the ships hull or wall surface, and fasten it at intervals
of about 40 cm.
• After fitting the interconnecting cable (see further ahead in this section):
The scanner cable has a connector fitted on the display side. Push the connec-
tor as far as it will go into the receptacle marked ‘RADAR’ on the rear of the
display cabinet and turn the connector’s coupling ring clockwise until it is
tight.