Installation manual

Cable inlet
Fix four screws
Ship’s
heading
Logo seal on
side wall
Installation 1-40 CX34/44/54-series
Interconnecting cable (RB714A + RB715A)
1. Run the cable, and fasten it at intervals of about 40 cm.
2. Remove the upper part of the radome from the scanner (loosen 4 screws).
Avoid bumping it against the antenna by lifting it vertically.
3. Remove the tape securing the antenna.
4. Remove the shield cover located on the astern side (4 screws).
5. Remove the cable clamping plate and rubber ring, pass the cable through
the cable inlet, place the rubber ring around the cable, and clamp the cable
to the scanner unit with screws via the fixing plate.
6. Refer to ‘Fitting interconnecting cable’ for RB714A and RB715A further on
in this section.
RB714A: Connect 10-pin connector to X1.
RB715A: Connect 7-pin connector to X11 and 9-pin connector to X12.
7. Replace the aluminum cover: Place the cable shield into the groove in the
aluminum cover. Be careful that the cable does not get caught between
main unit and cover, and that the antenna is free to rotate.
8. Replace the upper part of the radome: Be careful not to bump it against the
antenna. Be sure that the cover is fitted in the correct direction (refer to
below illustration). Align the upper and lower parts with the holes for the
screws and tighten the screws.
9. Ensure the display unit’s radar function is off. Connect the cable to the
receptacle marked RADAR on the rear panel of the display unit.