Operation Manual

7
Contents/Precautions
SH-08E_E_01.fm
[7/11]
Tablet
Desktop holder
Stylus pen
SH-08E is waterproof/dustproof, however, do not allow
water or dust to get inside the tablet and do not allow
accessories or optional parts to get wet or do not allow dust
to adhere.
The adapter, desktop holder, docomo mini UIM card and stylus pen
are not waterproof/dustproof. Do not use in humid or steamy areas
such as bathrooms and avoid exposing to rain and other forms of
moisture. If they are carried close to the skin, perspiration may cause
internal components to corrode and result in malfunction. Note that if
a problem is found to be due to moisture, the tablet and parts are not
covered by warranty and in some cases may be irreparable. Even
when repairs are possible, repair charges will be incurred, since the
damage is not covered by warranty.
Caution
Do not swing the tablet by the stylus pen when the
stylus pen is attached to the tablet.
May hit you or others around you, resulting in an accident
such as bodily injury.
Handling near electronic medical
equipment
Warning
If you have electronic medical equipment such as
an implanted cardiac pacemaker or an implanted
cardioverter-defibrillator, always carry or use your
tablet at least 15 cm away from your implant.
Electromagnetic signals may have harmful effects on the
operation of the electronic medical equipment.
Patients receiving medical treatment away from a
hospital or medical facility (e.g. home treatment)
who are using electronic medical equipment other
than implanted cardiac pacemakers or implanted
cardioverter-defibrillators should consult the
respective manufacturers for information regarding
the effects of signals on the equipment.
Electromagnetic signals may have harmful effects on the
operation of the electronic medical equipment.
If there is any chance that the distance between the
tablet and a person closest to you may get shorter
than 15 cm such as when you cannot freely move
around, set the tablet not to emit radio wave in
advance (by setting Airplane mode, turning the
power off, etc.).
Somebody nearby may be equipped with electronic medical
equipment such as an implanted cardiac pacemaker or an
implanted cardioverter-defibrillator. Electromagnetic signals
may have harmful effects on the operation of the electronic
medical equipment.
Follow the instructions given by the respective
medical facilities regarding the use of the tablet on
their premises.
Material list
Part Material/Surface treatment
Display side
Reinforced glass/Shatterproof
sheet of surface
Surrounding area of display side
PC-ASA resin/UV coating for
surface
Back
PC-ASA resin/UV coating for
surface
Surrounding area of main body
PC-ASA resin/UV coating for
surface, Discontinuous
deposition
docomo mini UIM card slot SUS/Ni plating
microSD Card slot SUS/Ni plating
External connector terminal
SUS/Sn plating, Copper alloy/
Gold plating
External connector terminal cover
PC resin/UV coating for
surface, Discontinuous
deposition
Gasket of external connector
terminal cover
Silicon
Earphone/Microphone terminal Copper alloy/Gold plating
Surrounding area of earphone/
microphone terminal
PA resin
Side key
PC resin/UV coating for
surface
Decoration of camera
PC-ASA resin/UV coating for
surface, Discontinuous
deposition
Camera panel
Acrylic resin/Printing on the
back
Mobile light PC resin
Mobacas/TV antenna PA resin
Metal section of Mobacas/TV
antenna
SUS
Charger/Power supply terminal SUS/Ni plating, Gold plating
Part Material/Surface treatment
Upper side case of main body ABS
Lower side case of main body ABS
Switch POM
Safety lever POM
Charger/Power supply terminal
C2200W/Gold plating, Sealing
treatment
Contact lever POM
Metal section of connector
terminal
Stainless steel
Insulated section of F-type
connector terminal
PS
Metal section of F-type connector
terminal
Zinc alloy/Ni plating
Screw SWCH/Black Ni plating
Stopper PORON
Part Material/Surface treatment
Top of pen
ABS resin/UV coating for
surface
Grip of pen Aluminum/Trivalent Cr plating
Decoration of tip of pen ABS resin
Tip of pen POM resin
Handling precautions
General notes
Part Material/Surface treatment
SH-08E_E.book 7 ペー 2013年6月28日 金曜日 午後3時7分