Owner`s manual

59
Plan Depth/Time information includes (Fig. 53A/B:
> NiBG (4 No Deco segments), or O2BG (4 segments),
indicating which (Nitrogen or Oxygen) is in control of
calculations based on previous dives.
> Dive Time (hr:min) allowed for the Depth displayed.
> Max Depth allowed for the PO2 Alarm value set with MAX
and FT (or M) icons and graphic - PO2.
> Tank 1 icon indicating Gas (mix) 1.
> Plan Depth with FT (or M) icon.
• Press and release the S button momentarily and repeatedly
(< 2 sec each time) to increase the Planned Depth in
increments of 10 FT (3 M), displaying the information one
screen at a time.
• Depressing the M button for 2 seconds, or if no button is
pressed for a period of 2 minutes, operation will revert to
the NORM Surface Main screen.
FLY MODE
Time to Fly is a counter that begins counting down 10 minutes
after surfacing from a dive from 23:50 to 0:00 (hr:min).
Ten minutes after a dive, operation reverts to the Watch Default
Time screen at which time the Time to Fly countdown continues
in the background. Access to the Fly screen is then gained by
first accessing the NORM (or GAUG) Surface Main screen.
Fig. 53B - PLAN
(Metric, O2 control)
Fig. 53A - PLAN
(Imperial, Ni control)