User`s manual

Setting the Conditions for Each Object Type
3-41
3
[6] Window group move
All the window positions set in the measurement
programs for the same object type number can be
shifted horizontally by a specified amount as a group.
[Example of use] Shift the coordinate positions used
as data for another object type.
(After copying the data between
object types, move the windows as
a group.)
To set the amount, use " MOVE ALL WINDOW" in
the" OBJECT TYPE SYS" menu.
1. While " SELECT CAMERA" is selected, press
the up and down arrow keys to select either
"CAM1" or "CAM2." Then press the SET key.
Note: When "CAM1&NG IMGS" is selected for the
" MONITOR OUTPUT," the " SELECT
CAMERA" item is limited to "CAM1."
See page 1-19 for details about the " MONITOR OUTPUT."
2. Select " STR COORD POSI" (store coordinate position) and press the SET key. Then select
"MOVE" by using the left and right arrow keys and finally, press the SET key.
3. Move the cursor (solid line) to the original coordinates before the move using the up, down, left, and
right keys, and press the SET key.
4. Select "COORDINATES STORED" using the left and right keys, and press the SET key. After that
press the ESC key.
The coordinates before the move are now registered.
5. Select " MOVE ALL WINDOW" using the up and down keys and press the SET key. Select
"MOVE" using the left and right keys and press the SET key.
6. Move the cursor (dotted line) to the new coordinates you are moving to use the up, down, left, and
right keys and press the SET key.
7. Select "EXEC" (execute) using the left and right keys and press the SET key.
All the windows registered to the same object type will be shifted horizontally at the same time by the
distance between the original coordinates to the new coordinates. After the move is complete, a
"Window group move is complete" message will be displayed.
- When some part of the window to be moved will move outside of the image display area, the "Out
of range" message will be displayed together with the measurement number and register number.
In this case, select "Continue" or "Halt."
If "Continue" is selected, the window will be shifted to the limit within the image display area.
Coordinates of
the original
Distance to
move A
Coordinates
of the new
Original window
Distance to move A
New window
MOVE ALL WIN SCREEN SAVE F C1 BRT
1
SELECT CAMERA CAM1
2
STR COORD POSI MOVE(256,240) COORDINATES STORED
3
MOVE ALL WINDOW MOVE(256,240) EXEC
Displayed when the
IV-S32MX/S33MX
is used.
1
REGST NG IMG YES
2
HALT ON NG MEAS YES
3
MNTR LIGHT LVL(CAM1) YES
4
LIGHT LV COND (TO NEXT SUB-BENU)
5
MNTR LIGHT LVL(CAM2) YES
6
LIGHT LV COND (TO NEXT SUB-MENU)
7
MOVE ALL WINDOW (TO NEXT SUB-MENU)
OBJ-TYPE SYS. SCREEN SAVE
F C1 BRT