7
BGA/CSP Inspection
1
REGISTER NO. 0(0~3) [TEST RESULT] [OUTPUT]
2
CONDITION SET AUTO(
±
10%)
3
NUMBER OF OBJ 000~128 K= NO
4
TOTAL AREA 000000~245760 A= NO
5
OBJECT AREA 000000~245760 R= NO
6
X DIRECT SPACE 000.0~511.0 DX= NO
7
Y DIRECT SPACE 000.0~479.0 DY= NO
8
X FILLET WIDTH 000~511 FX= NO
9
Y FILLET WIDTH 000~479 FY= NO
0
TEST EXEC(WITH-POSI.ADJ WITHOUT-POSI.ADJ)
SET=VALUE INPUT ESC=BACK SEL=CHNG IMG TRG=FUNC
F C1 BRTEVALUAT COND SCREEN COND SAVE EDIT SEL
F C1 DRK
V*.**
(TYPE00)
OK
MEAS XXXXms 2001-10-14 10:38
MEASUREMENT 1 INSPECT BGA/CSP
REGISTER N00(0~15)
K=006 OK
A=008492 OK
R=001450 OK
  001383 OK
DX=138.2 OK
  136.4 OK
DY=409.6 OK
  407.8 OK
FX= 031 OK
  030 OK
FY= 031 OK
  030 OK
MNU-CHG MAIN-COND CHG-MEA COND-CHG CHNG-REG SCREEN-CHG CHG-TYPE
X07
□□□□□□□□  
Y07
□□□□□□□□  
READY
NUMBER OF OBJ
TOTAL-AREA
OBJECT-AREA
(Max./Min. : Number of pixels)
X DIRECT SPACE
(Max./Min. : Number of pixels)
Y DIRECT SPACE
(Max./Min. : Number of pixels)
X FILLET WIDTH
(Max./Min. : Number of pixels)
Y
FILLET WIDTH
(Max./Min. : Number of pixels)
[Display of the inspection results]
Final evaluation result
Measuring time
Measurement program number
Registration number of
measurement condition
The "EVALUAT COND"(evaluation conditions)
screen will appear.
For details about the evaluation conditions,
see page 3-18.
Numeric calculation setting
- Press the TRG/BRT key to move the cursor to the upper function menu, and highlight "COND"
using the left and right arrow keys. Press the SET key to show the popup menu. Select "NUM-
CALC" from the popup menu.
- Select "NUM-CALC" on the menu tree.
See "Chapter 15: Numeric calculation."
Output condition setting
- Press the TRG/BRT key to move the cursor to the upper function menu, and highlight "COND"
using the left and right arrow keys. Press the SET key to display the popup menu. Select "OUT"
from the popup menu.
- Select "OUT-COND" on the menu tree.
See "Chapter 17: Set the Input/Output Conditions."
Display the inspection results
Return to the operation screen and press the TRG/BRT key. The inspection results will be displayed
on the screen.