User`s manual

1-7
Setting and Operating Outline
1
STEP6
SELECT INSPECTION PRECISION
1
STANDARD(PIXEL)
2
HIGH(SUB-PIXAEL)
RETURN NEXT
REG COND SCREEN COND SAVE DETAIL
EVALUAT COND SCREEN COND SAVE EDIT SEL
F C1 BRT
1
REGISTER NO. 0(0~7) [TEST RESULT] [OUTPUT]
2
CONDITION SET AUTO(–10%)
3
X COORD. (MDL0) 000.0~511.0 X0= NO
4
Y COORD. (MDL0) 000.0~479.0 Y0= NO
5
x DEVIATE (MDL0) -511.0~+511.0 x0= NO
6
y DEVIATE (MDL0) -479.0~+479.0 y0= NO
7
MATCH LVL(MDL0) -10000~+10000 M0= NO
8
TEST EXEC(WITH-POSI.ADJ WITHOUT-POSI.ADJ)
STEP5
1
REGISTER NO.(0~7) 0
SELECT AN IMAGE PROCESSING
1
NO
2
GRAY-SRC
3
EDGE DTECT
4
SCH-EDGE
1
NUM.OF DTECT 1P
ENTER A RANGE AND UNITS FOR
ROTATION ANGLE DETECTION
1
DTECT ANGL NO
RETURN NEXT DETAIL
STEP4
SELECT TYPE OF CALCUATION
BETWEEN IMAGES
1
COMPARE IMGS NO
SELECT WHETHER OR NOT TO
CONVERT IMGE DENSITY
1
CHNG GRAY LEVELNO
SELECT FILTER TYPE FOR
IMAGE DATA
1
SPACE FILTER NO
RETERN NEXT DETAIL
1
REGISTER NO. 0(0~7)
2
MEAS SHAPE(MDL0) RECTANGLE
3
REFIMG AARE(MDL0) SET (224,208)~(287,271)
4
SEARCH ARE(MDL0) SET (216,200)~(295,279)
STEP7
1Displayed when the "CAM1" or "CAM1&2" is selected in item "1COMPARE IMGS"
COMPARE IMGS SCREEN SAVE
1
CALC.TYPE NO
2
CALC.AREA SET (232,216)-(279,263)
COMPARE EVALUATION
CONDITIONS TO MEASUREMENT
RESULTS (YES/NO)
1
NO
2
YES
RETURN NEXT DETAIL