User`s manual

8-7
8
Area Measurement by Binary Conversion
Set the evaluation conditions
How to move to the evaluation condition setting screen
There are two methods for getting to the evaluation condition setting screen.
1) Select "COND" in the upper function menu on
the MEAS COND (or REG COND) screen and
press the SET key.Select "EVALUATION" on
the pop up menu to go to the EVALUAT COND
screen.
2) Move the cursor to the "EVALUATION COND"
item on the menu tree screen and press the
SET key.
The "EVALUAT COND" (evaluation conditions)
screen will appear.
For details about the evaluation conditions,
see page 3-18.
F C1 BRTSELECT OBJECT TYPE COND
OBJECT TYPE COND
  
TYPE00
TYPE01
TYPE RUN COND
IMAGE-ADJ
MEA-CND(CAMERA1)
MEAS0
POSI-DEVIATION
MEAS01(MEAS-BIN-AREA)
IMG PRE-PROC
MEAS CND
REG-COND
EVALUATION COND
NUM-CALC
OUT-COND
MEAS(NEW)
MEA-CND(CAMERA2)
FINAL NUM. CALC
FINAL OUTPUT COND
OBJ-TYPE I/O
OBJ-TYPE SYS.
SET=TO NEXT SUB-MENU ESC=BACK SEL=CHNG IMG TRG=POPUP
+
+
1
CHNG REG
2
CONDITION SET
3
REGISTER 00
4
REGISTER 01
5
REGISTER 02
6
REGISTER 03
7
REGISTER 04
8
REGISTER 05
9
REGISTER 06
0
REGISTER 07
q
TEST
1
CHNG REG [TEST RESULT] [OUTPUT]
2
CONDITION SET AUTO(
±
10%)
3
REGISTER 00 000000~245760 A00= NO
4
REGISTER 01 000000~245760
5
REGISTER 02 000000~245760
6
REGISTER 03 000000~245760
7
REGISTER 04 000000~245760
8
REGISTER 05 000000~245760
9
REGISTER 06 000000~245760
0
REGISTER 07 000000~245760
q
TEST EXEC(WITH-POSI.ADJ WITHOUT-POSI.ADJ)
SET=EXEC ESC=BACK SEL=CHNG IMG TRG=FUNC
F C1 BRTEVALUAT COND SCREEN COND SAVE EDIT SEL
MEA-CND
SCREENCONDSAVE
1
WINDOW
BINARY-IMG-MASK
2
REGISTER NO.
0
3
REGISTER EXIST YES
4
MASK BINARY IMG
REF-IMG
5
BIN IMG MASK
(TO NEXT SUB-MENU)
REGISTER NO.
6
BIN AREA COND
15141312111009080706050403020100
F C1 BRT
SET=SELECT A MENU ESC=BACK SEL=CHNG IMG TRG=FUNC
IMG PRE-PROC
REG COND
EVALUATION
NUM-CALC
OUT