User`s manual

9-8
Object Counting by Binary Conversion
9
Numeric calculation setting
- Press the TRG/BRT key to move the cursor to the upper function menu, and highlight "COND" using
the left and right arrow keys. Press the SET key to show the popup menu. Select "NUM-CALC" from
the popup menu.
- Select "NUM-CALC" on the menu tree.
See "Chapter 15: Numeric calculation."
Output condition setting
- Press the TRG/BRT key to move the cursor to the upper function menu, and highlight "COND" using
the left and right arrow keys. Press the SET key to display the popup menu. Select "OUT" from the
popup menu.
- Select "OUT-COND" on the menu tree.
See "Chapter 17: Set the Input/Output Conditions."
Display the measurement results
Return to the operation screen and press the TRG/BRT key. The measurement results will be displayed
on the screen.
F C1 BRT
V*.**
(TYPE00)
OK
MEAS XXXXms 2001-10-14 10:38
MEASUREMENT 1 CNT-BIN-OBJ
K0=00006 OK
A0=015781 OK
K1=00020 OK
A1=087620 OK
K2=00010 OK
A2=042680 OK
K3=
A3=
MNU-CHG MAIN-COND CHG-MEA COND-CHG CHNG-REG SCREEN-CHG CHG-TYPE
X07 Y07 READY
Final evaluation result
[K] of resistration number 0
[A] " 0
[K] " 1
[A] " 1
[K] " 2
[A] " 2
[K] " 3
[A] " 3
in the measurement condition
[K]=NUMBER OF OBJECTS
[A]=TORAL AREA
(Number of pixels)
Measurement
program
Measuring time
- Areas will not be displayed
for unspecified registration
numbers.