User`s manual

11-6
Existence Inspection by Point Measurement
11
STORE BLOCK COND
Press the TRG/BRT key to move the cursor to the upper function menu. Select "DETAIL" and press the
SET key. Select "STORE BLCK OF PNTS" from the popup menu and press the SET key. Now, items
to will be displayed on the "REG COND" menu.
This function is used to set a group of points at the same time, after specifying the number of points
horizontally and vertically and their spacing.
REGISTER NO.
When "AND" or "OR" is selected on the
" EVALUATION" line, select "YES" at the
REGISTER NO" item. Then, " UPPER
LEFT" will be displayed.
UPPER LEFT
Specify the coordinates of the upper left
corner of the block you want to register.
BLOCK ARRANGEMENT
Enter the number of points along the X
(horizontal) and Y (vertical) axes.
BLOCK SPACING
Specify the distance between the points in
the horizontal and vertical rows.
STORE BLCK OF PTS
Select "EXEC" and press the SET key to register the block.
DEL BLOCK OF PTS
Delete all the points that were registered at the same time.
MOVE BLOCK OF PTS
Move the group of points that were registered at the same time.
Example of a block registration
Set the starting point in item 5 above.
XX
Y
Enter 002 (vertical) · 003 (horizontal) in item "6BLOCK ARRANGEMENT,"
and enter the vertital (Y) and horizontal (X) intervals in item
"7BLOCK SPACING." Then select item "8STORE BLOCK OF PTS"
to store the settings for the block.
1
SIZE Y08
×
X08(2~32)
2
EVALUATION MAJORITY
3
EVAL-SPEC(RATIO
) 050
4
REGISTER NO. 000(0~255)YES
5
UPPER LEFT MOVE(224.208)
6
BLOCK ARRANGEMENT Y001
×
X001
7
BLOCK SPACING Y004
×
X004
8
STORE BLCK OF PTS EXEC
9
DEL BLOCK OF PTS EXEC
0
MOVE BLOCK OF PTS MOVE(224.208)
REG COND SCREEN COND SAVE DETAIL
F C1 BRT
SEL=MOVE ESC=BACK SEL=CHNG IMG TRG=FUNC
STORE BLCK OF PNTS
NO
YES