User`s manual

12-10
Multiple Positional Measurement
12
2) Move the cursor to the "EVALUATION COND"
item on the Menu tree screen and press the
SET key.
The "EVALUAT COND"(evaluation conditions) screen will appear.
For details about the evaluation conditions, see page 3-18.
- When "GRAY-SRC" is selected on line "
MODE."
- When "EDGE DTECT" is selected on line "
MODE."
Numeric calculation setting
- Press the TRG/BRT key to move the cursor to the upper function menu, and highlight "COND" using
the left and right arrow keys. Press the SET key to show the popup menu. Select "NUM-CALC" from
the popup menu.
- Select "NUM-CALC" on the menu tree.
See "Chapter 15: Numerial calculations."
Output condition setting
- Press the TRG/BRT key to move the cursor to the upper function menu, and highlight "COND" using
the left and right arrow keys. Press the SET key to display the popup menu. Select "OUT" from the
popup menu.
- Select "OUT-COND" on the menu tree.
See "Chapter 17: Setting the Input/Output Conditions.
1
REGISTER NO.
2
CONDITION SET
3
NUMBER OF OBJ
4
DTECT NUMBER
5
MATCH LVL
6
TEST
F C1 DRKSELECT OBJECT TYPE COND
OBJECT TYPE COND
  
TYPE00
TYPE RUN COND
IMAGE-ADJ
MEA-CND(CAMERA1)
MEASO
POSI-CORRECT
MEAS01(MULTI-POSI)
IMG PRE-PROC
MEAS CND
REG-COND(S)
REG-COND(E)
EVALUATION COND
DISTANCE&ANGLE COND
NUM-CALC
OUT-COND
MEAS(NEW)
MEA-CND(CAMERA2)
FINAL NUM. CALC
FINAL OUTPUT COND
OBJ-TYPE I/O
OBJ TYPE SYS.
SET=TO NEXT SUB-MENU ESC=BACK SEL=CHNG IMG TRG=POPUP
+
+
1
REGISTER NO. 0(0~3) [TEST RESULT] [OUTPUT]
2
CONDITION SET AUTO(–10%)
3
NUMBER OF OBJ 000~128 K= NO
4
DTECT NUMBER 000~(0~000)
5
MATCH LVL -10000~+1000 M0= NO
X COORD. X0=
Y COORD. Y0=
6
TEST EXEC(WITH-POSI.ADJ WITHOUT-POSI.ADJ)
F C1 BRTEVALUAT COND SCREEN COND SAVE EDIT SEL
1
REGISTER NO. 0(0~3) [TEST RESULT] [OUTPUT]
2
CONDITION SET AUTO(–10%)
3
NUMBER OF OBJ 000~128 K= NO
4
DTECT NUMBER 000~(0~000)
X COORD. X0=
Y COORD. Y0=
5
TEST EXEC(WITH-POSI.ADJ WITHOUT-POSI.ADJ)
F C1 BRTEVALUAT COND SCREEN COND SAVE EDIT SEL