User`s manual

13-2
Multiple Degree of Match Inspection
13
13-2 Setting operation
Setting the measurement conditions
How to enter the measurement conditions setting screen
Select "MAIN-COND" -> "OBJECT TYPE COND"
(menu tree)-> "TYPE00" ->"MEA-CND
(CAMERA1)" -> "MEAS(NEW)," in that order.
Then press the SET key to bring up the "MEAS1"
screen.
Move to the " MEAS SELECTION" line on the
"MEASUREMENT1" screen and select "MULTI
MATCHES" from the popup menu.
Press the ESC key to return to the "OBJECT TYPE COND" (menu tree) screen, and select the "MEAS
CND" item shown under "MEAS01 (MULTI MATCHES)" to go to the "MEAS CND" screen.
For details, see "Chapter 8: Setting Examples Using the Menu Tree" in the Introduction and
Hardware.
SET=WINDOW SET ESC=BACK SEL=CHNG IMG TRG=POPUP
F C1 BRT
OBJECT TYPE COND
TYPE00
TYPE RUN COND
IMAGE-ADJ
MEA-CND(CAMERA1)
MEAS0
POSI-CORRECT
MEAS(NEW)
MEA-CND(CAMERA2)
FINAL NUM. CALC
FINAL OUTPUT COND
OBJ-TYPE I/0
OBJ-TYPE SYS.
TYPE(NEW)
SELECT OBJECT TYPE COND
+
+
1
MEAS SELECTION
NO
POSI-DEVATION
CHK-DEG-MATCH
INSPECT-LEAD
INSPECT-BGA/CSP
MEAS-BIN-AREA
CNT-BIN-OBJ
LABEL-BIN-OBJ
POINT-MEAS
MULTI-POSI
MULTI MATCHES
SET=SELECT A MENU ESC=BACK SEL=CHNG IMG TRG=FUNC
F C1 BRT
MEASUREMENT1 SCREEN COND SAVE
1
MEAS SELECTION MULTI MATCHES