User`s manual

13-4
Multiple Degree of Match Inspection
13
How to set the register conditions
How to enter the REG-COND setting screen
There are three methods for getting to the REG-COND setting screen.
1) On the "MEAS CND" setting screen, move
the cursor to the " DETECT OBJECT" and
press the SET key. The cursor will move into
the table. Move the cursor to the "S" column
and press the SET key.
Note: If you press the SET key in the "X"
column, the setting will be invalid.
2) On the "MEAS CND" setting screen, press the
TRG/BRT key to move the cursor to the upper
function menu. Select the "COND" item and
then select the "REG COND" item and press
the SET key.
3) On the menu tree, move the cursor to the
"MEAS CND" item, and press the right arrow
key. The sub menu which contains the "REG
COND" item will appear. Move the cursor to
this item and press the SET key.
Register a reference image
After setting the reference image area, store
an image in the controller as a reference
image.
Select " REF-IMG AREA" using the up/
down arrow keys and select "REG" from the
popup menu.
MEAS CND SCREENCONDSAVE
1
DTECT PRECISION STANDARD
2
REGISTER NO.
0(0~3)
3
MODE
NO
4
MATCHING AVG-GRAYS
5
DETECT ORDER SCAN-ORDER
REGISTER NO.
6
DTECT OBJECT
15141312111009080706050403020100
× ×
F C1 DRK
SET=VALUE INPUT ESC=BACK SEL=CHNG IMG TRG=FUNC
IMG PRE-PROC
REG-COND
EVALUATION
DST&ANGL
NUM-CALC
OUT
1
REGISTER NO.
F C1 BRTSELECT OBJECT TYPE COND
OBJECT TYPE COND
  
TYPE00
TYPE RUN COND
IMAGE-ADJ
MEA-CND(CAMERA1)
MEAS0
POSI-CORRECT
MEAS01(MULTI MATCHES)
IMG PRE-PROC
MEAS CND
REG-COND
EVALUATION COND
DISTANCE&ANGLE COND
NUM-CALC
OUT-COND
MEAS(NEW)
MEA-CND(CAMERA2)
FINAL NUM. CALC
FINAL OUTPUT COND
OBJ-TYPE I/O
SET=TO NEXT SUB-MENU ESC=BACK SEL=CHNG IMG TRG=POPUP
+
+
+
1
REGISTER NO.
0(03)
2
REF-IMG AREA SET (224.208)(287.271)
3
SEARCH AREA SET (216.200)(295.279)
4
MATCH LVL(CONTR) +05000
5
MATCH LVL +07000
REG COND
   
SCREEN COND
SAVE DETAIL F C1 BRT
SEL=WINDOW SET ESC=BACK SEL=CHNG IMG TRG=FUNC
Object to measure
Search area
Search direct