User`s manual

13-6
Multiple Degree of Match Inspection
13
SEARCH AREA
Specify the search area (inside the dotted lines) on the " SEARCH AREA" line, using the same
procedures used for setting the reference image area.
DTECT COORD (detection coordinates)
Select whether to use the detection
coordinates as the center of the reference
area or to allow the point to be set freely.
CENTER: The center of the rectangular area
will automatically be used for the
detection coordinates.
SET: You can specify any position in the
rectangular area to be used for the
detection coordinates.
Set degree of match
MATCH LVL (CONTR)
Specify the degree of match used for detection in the contracted images (detects contracted
shapes in images whose value is larger than the specified reference value).
MATCH LVL
Specify a degree of match used for detection in the original images of the contracted images that
were detected in the search at line " MATCH LVL" (detects original images which are larger
than the specified value).
1
REGISTER NO.
0(03)
2
REFERENCE IMG 015(000~026)
3
REF-IMG AREA SET (224.208)(287.271)
4
SEARCH AREA SET (216.200)(295.279)
5
DTECT COORD CENTER (223.241)
6
CONTR.PIXEL 3
7
MATCH LVL(CONTR) +05000
8
MATCH LVL +07000
REG COND
   
SCREEN COND
SAVE DETAIL F C1 BRT
SEL=WINDOW SET ESC=BACK SEL=CHNG IMG TRG=FUNC
CENTER
SET
■An example
Object to measure
Seach area