(6) Degree of match inspection
Press the TRG/BRT key, and the will calculate the X-Y coordinates of the detection points in images 0
and 1, and then evaluate and output the results.
Output conditions
Final output conditions
- If the result is within the range,
N00 and N01 will be turned ON
(OK), the auxiliary relay C000
will be turned ON, and output
Y00 will be turned ON.
Y00
C000
C000
N00 N01
X0∼7 Y0∼7 READY
REGISTER N00(0~15)
M0=+09735 OK
X0= 090.0 OK
Y0= 092.0 OK
G0= 018.0 OK
(TYPE00)
OK
MEAS XXXXms 2001-10-14 10:38
MEASUREMENT 1 CHK-DEG-MATCH
F C1 BRT
V*.**
If the difference in the X and Y coordinates is within the range set on the numeric
calculation menu, Y0 will be turned ON, and a filled box will be displayed. If the
difference is not within the range, Y0 will be turned OFF, and an empty box will be
displayed.