User`s manual

16-3
PC Function
16
16-3 Ladder circuit program creation
[1] Procedure for creating measurement output condition and a ladder circuit
A separate ladder circuit can be created for positional deviation measurement, degree of match
inspection, lead inspection, BGA/CSP inspection, area measurement by binary conversion, object
counting by binary conversion, object identification by binary conversion, point measurement, multiple
position measurement, and multiple degree of match inspection.
The procedure for creating a ladder circuit for positional deviation measurement is given below. A
ladder circuit can be created the same way for other measurement just change the input contact point
setting.
(1) How to display the output conditions setting screen.
There are two methods for displaying the output conditions setting screen, as follows.
1. On the menu tree, open the sub menu at
"MEAS01(POSI-DEVIATION)." Press the SET
key on the "OUT-COND" line.
2. On the screen used for selecting the
measurement program, or on the screens
used for setting the measurement conditions
or the register conditions, press the TRG/BRT
key to move the cursor to the upper function
menu. Then, move the cursor to the "COND"
and press the SET key. Select "OUT" from the
popup menu.
OBJECT TYPE COND
TYPE00
TYPE RUN COND
IMAGE-ADJ
MEA-CND(CAMERA1)
MEAS0
POSI-CORRECT
MEAS0(POSI-DEVIATION)
IMG PRE-PROC
MEAS CND
REG-COND(S)
REG-COND(S)
EVALUATION COND
DISTANCE&ANGLE COND
NUM-CALC
OUT-COND
MEAS(NEW)
MEA-CND(CAMERA2)
FINAL NUM.CALC
FINAL OUTPUT COND
+
+
SET=TO NEXT SUB-MENU ESC=BACK SEL=CHNG IMG TRG=POPUP
SELECT OBJECT TYPE COND
F C1 BRT
INPUT0
LOGIC
INPUT1
LOGIC
INPUT2
LOGIC
INPUT3
LOGIC
INPUT4
LOGIC
INPUT5
LOGIC
INPUT6
LOGIC
INPUT7
LOGIC
1
MEAS SELECTION 0(0~7)
IMG PRE-PROC
REG-COND(S)
EVALUATION
DST&ANGL
NUM-CALC
OUT
SET=SELECT A MENU ESC=BACK SEL=CHNG IMG TRG=FUNC
F C1 DRK
MEASUREMENT1 SCREEN COND SAVE