User`s manual

16-12
PC Function
16
(2) How to specify the input conditions for ladder circuit diagrams
1. While "CHANGE INPUT" is selected, each
press of the SET key will change the display in
the leftmost row. The display will cycle through
the following choices: "INPUT00 to INPUT07,"
"INPUT08 to INPUT15," "INPUT16 to
INPUT23," and "INPUT24 to INPUT31." When
the input group you want is displayed, press
the down arrow key to move the cursor to the
ladder circuit display section.
2. Move the cursor to a line number (INPUTxx)
and a row using the up/down/left/right arrow
keys, and press the SET key. Select a type to
input from the popup menu.
3. After selecting an input type, press the SET
key and move the cursor to a logic line.
4. Press the SET key and select a logic symbol
from the popup menu.
Logic symbol Function
Deletes a contact on the cursor. (Contacts after the deleted contact will not be
brought forward.)
Note: This symbol cannot be used on the first row.
Deletes the contact on the cursor. (Contacts after the deleted contact will be
brought forward.)
When a contact exists only on the first row, if the contact is deleted, also the
output relay will be deleted.
a contact on a series circuit (ON, when the evaluation result is OK)
b contact on a series circuit (OFF, when the evaluation result is OK)
Used to create an OR circuit.
Used to create an OR circuit
DEL
OUTPUT COND SCREEN SAVE
INPUT00-07
CHANGE
INPUT
INPUT00
LOGIC
INPUT01
LOGIC
INPUT02
LOGIC
INPUT03
LOGIC
INPUT04
LOGIC
INPUT05
LOGIC
INPUT06
LOGIC
INPUT07
LOGIC
F C1 BRT
SET=SELECT LOGIC SYMBOL SEC=BACK SEL=CHNG IMG TRG=FUNC
DEL
0  1  2  3  4  5  6  7 
OUT
00
M
0
OUTPUT COND SCREEN SAVE
INPUT00-07
CHANGE
INPUT
INPUT00
LOGIC
INPUT01
LOGIC
INPUT02
LOGIC
INPUT03
LOGIC
INPUT04
LOGIC
INPUT05
LOGIC
INPUT06
LOGIC
INPUT07
LOGIC
F C1 BRT
SET=SELECT TYPE SEC=BACK SEL=CHNG IMG TRG=FUNC
AUX.RLY-C
EXT-INP X
TMR TM
CNTR CN
AN
OUTPUT Y
Column No. 0 to 7
Row No.
0  1  2  3  4  5  6  7 
OUT
00
M
0
Ladder circuit
display area