User`s manual

17-6
Setting the Input/Output Conditions
17
Setting order 1 (2)
Configuration example
External trigger X0
(photo sensor or
proximity sensor)
Type selection switch
-See page 17-5.
Controller
Power supply
(24 V DC)
Monitor
Camera 1 (image capturing)
Camera 2 (image capturing)
Remote keypad
External output
(Y0 to Y7)
Warning lamp
I/O CONDITIONS
1MEAS INP I/F
2OUT I/F(PARAL.)
PARALLEL+SERIAL+USB
TRIG CCD START
NO
PC-LINK
SERIAL
Specified object type number Specified object type number
Type selection
input
Measurement
start input
(X0)
10 ms
or more
10 ms
or more
10 ms
or more
PC calculation
condition
Parallel output
(Y0 to Y7)
Halt PC operation during
measurement
Halt PC operation during
measurement
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
Parallel output is valid for PC control
after the measurement result is
determined.
When the object type is
changed, all Y output and
auxiliary relays turn OFF.
Result output Result output
Image capture
Image
disposition
Image
disposition
End of the measurement
Image capture
Custom:Final output condition
Y00
C119
End of the measurement
READY output
When you set the READY
ON signal to "CAPTURE
COMPLETE."
- See page 17-3.
When you set the
READY ON signal to
"MEAS COMPLETE."
- See page 17-3.
Note: When the READY signal is turned ON, the measurement start input will be enabled. To detect the
end of the measurement, you have to create a ladder circuit pointing at the Y output for auxiliary
relay C119 (end of the measurement).
Time chart
(1) Measurement start input = parallel, object type change = parallel, result output = parallel
- The conditions for outputting the results to the output signals Y0 to Y7 are set by the PC function. (See
"Chapter 16 PC Function.")