User`s manual

17-7
Setting the Input/Output Conditions
17
Setting order 1 (2)
Programmable
controller
Configuration example
External trigger X0
(photo sensor or
proximity sensor)
Controller
Power supply
(24 VDC)
Monitor
Camera 1 (image capturing)
Camera 2 (image capturing)
Remote keypad
Data
(Computer link)
Object type change
(parallel IF)
-See page 17-5.
I/O CONDITIONS
1MEAS INP I/F
2OUT I/F(PARAL.)
PARALLEL+SERIAL+USB
TRIG CCD START
NO
PC-LINK
SERIAL
- The data in a specified block No., set in item " SET SERIAL BLOCK" on the "OBJ-TYPE I/O"
screen, will be output through the computer link. See page 17-23.
Time chart
(2) Measurement start input = parallel, object type change = parallel, result output = computer
Iink/parallel
When a Sharp PC is used, a write enable command (EWR) is transmitted from the IV-S30 to the PC
in the following cases.
- When the power is applied to the IV-S30.
- When a write mode nonconformity error (code 10(H)) occurs after a result write command (WRG)
is transmitted (when the power is disconnected from the PC).
-When the output method is changed from the "OUT I/F (PARAL.)" to the "COMPUTER LINK."
Terminate
measurement
(C119)
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
Result output
Result
output
Result
output
Result output
Measurement
start input
(X0)
10 ms
or more
10 ms
or more
10 ms
or more
Specified object type number Specified object type number
Computer link outputoutput
Measurement result is valid at the end
of a measurement
READY signal is turned ON at the
conclusion of the result output.
PC calculation
condition
Halt PC operation during
measurement
Halt PC operation during
measurement
When the object type is
changed, all Y output and
auxiliary relays turn OFF.
Parallel output is valid for
PC control after the
measurement result is
determined.
Parallel output
(Y0 to Y7)
a
a
READY output
(While measuring or setting = L)
Type selection
input
See page