User`s manual

17-13
Setting the Input/Output Conditions
17
Configuration example
Monitor
Camera 1 (image capturing + CCD trigger)
Camera 2 (image capturing)
Personal computer
Remote key pad
Sampling start,
object type change
Data
Controller
Power supply (24 VDC)
IV-S3M
OUTPUT
INPUT
POWER
Y7Y0 Y1 Y2 Y3 Y4 Y5 Y6
COM
COM
24V
X7X0 X1 X2 X3 X4 X5 X6
READY
0V
VIDEO
CAMERA1
CAMERA2
USB
RS232C/RS422
REMOTE
Setting order 12
2
START CCD SAMPL
AUTO(EDGE)
AUTO(LEVEL)
PARALLEL
SERIAL+USB
1MEAS INP I/F
PARALLEL+SERIAL+USB
TRIG CCD START
(8) Measurement start input = CCD trigger, start sampling, object type change = general purpose
serial, result output = general purpose serial/parallel
The CCD trigger is enabled after a measurement execution command is entered.
-See Chapter 18 for details about the measurement execution commands (codes 10, 11, 12 and
14(H)).
- When one of the measurement execution commands (codes 10, 11, 12 and 14(H)) is normally
received during sampling, the sampling will stop.
Note: When the settings listed in section "17-3 CCD trigger" have not been made, a "CCD TRIG
NOT SET. (error 34)" will occur.
Time chart
Note: Result output: The data in the block No., set in item " SET SERIAL BLOCK" on the
"OBJ-TYPE I/O" screen, will be transmitted to the personal computer. See page 17-
23.
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
P
C
Result
output
Result
output
Serial
Result outputResult output
CCD trigger
cycle
Start CCD
sampling by
turning ON
measurement
start input .
READY signal is turned ON
at the conclusion
of the result output.
Stop CCD sampling
by measurement
command.
CCD trigger
window
(not highlighted)
Black BlackWhite
Trigger Trigger
Terminate
measurement
(C119)
Measurement result is valid at the
end of a measurement
PC calculation
condition
Parallel output
Halt PC operation
during measurement
Halt PC operation
during measurement
When the object type is changed,
all Y output and auxiliary relays
turn OFF.
Parallel output is valid for PC control after
the measurement result is determined.
Mesurement
trigger
command
Mesurement
trigger
command
Mesurement
trigger
command
Mesurement
trigger
command
READY output
(While measuring
or setting = L)