User`s manual

1-19
Setting and Operating Outline
1
[2] How to display NG images
NG images can be displayed on the operation main screen and on the NG image display screen (IV-
S32MX/S33MX).
(1) Displaying NG images on the MAIN OPS menu
An NG image (the latest or any previous NG image) recorded with camera 1 can be displayed on the
monitor while conducting measurements from the operation main screen.
- This function only refreshes the NG image if another NG is captured. The screen is not refreshed
with normal image measurement results. Thus, this method is useful for an operation that has a
short cycle time and needs to process another workpiece soon after saving the NG image.
-When the measuring is stopped, NG images can also be displayed on the NG image display
screen. See page 1-22.
The setting procedures are as follows:
1. Select "CAM1&NG-IMG" from the monitor
output.
See page 1-17 to1-18
2. Set the monitor output to "NG-IMGS" or
"CAM1&NG-IMG."
Select " MONITOR OUTPUT" on the [TYPE
RUN COND] menu.
See page 2-3.
When the IV-S33MX is used
When the IV-S31MX/S32MX is used
Description
MONITOR OUTPUT
CAM1
NG-IMGS
CAM1&NG-IMG (HORIZ)
CAM1&NG-IMG (VERT)
Display the camera 1 image on the whole screen.
Display the NG image on the whole screen.
Display the camera 1 image on upper half, and the NG image on lower half.
Display the camera 1 image on left half, and the NG image on right half.
TYPE RUN COND SCREEN SAVE
F C1 BRT
SET=SELECT A MENU ESC=BACK SEL=CHNG IMG TRG=FUNC
1
MONITOR OUTPUT
NG INGS
2
CAPTUR IMG
PARTIAL-IMG
3
MESSAGE DISPLAY
YES(NUMERIC)
4
PATTERN DISPLAY
YES
5
SHOW BINARY
YES
6
SHOW θFIX IMG
YES
7
OPS MAIN DISP
YES
8
DISP CHG-EVAL
NO
9
PC-MNTR
NO
0
THROUGH DISPLAY NO
q
EXTENSION FUNC. NO
CAM1
NG IMGS
CAM1&NG-IMG(HORIZ)
CAM1&NG-IMG(VERT)
Displayed when the
IV-S33MX is used.
Description
MONITOR OUTPUT
CAM1
NG-IMGS
CAM1&NG-IMG
Display the camera 1 image on the whole screen.
Display the NG image on the whole screen.
Display the camera 1 image on upper half, and the NG image on lower half.