The IV-S30 calibration can be adjusted, e.g. "1 pixel = 1 mm", and the data can be displayed as
actual dimensions.
How to display the CALIBRATION setting screen
1) Select "MAIN COND" and then "OBJECT
TYPE COND."
2) On the "OBJECT TYPE COND" screen, move the cursor to any "TYPExx" that you want to
calibrate, and press the SET key.
3) Move the cursor to the "OBJ-TYPE I/O" line
and press the SET key.
4) On the "OBJ-TYPE I/O" setting screen, move
the cursor to the " CALIBRATION" line and
press the SET key twice, to bring up the sub-
menu.
Note: Depending on settings for the " TRIG
CCD START" and " SERIAL
OUTPUT" items, the number of the
"CALIBRATION" line will vary between
and .
5) Set the calibration details on the
"CALIBRATION" setting screen.
Put a ruler in the camera’s field of view .
When "MANUAL" is selected on the "CALIBRATION" line
1. Move the cursor to " CURSOR1-COORD" and press the SET key.
IVS3*MX
SYS-CND
OBJECT TYPE COND
SET WIZARD
EDIT MAIN OPS MENU
OPTION
F C1 BRTMAIN MENU
+
+
+
OBJECT TYPE COND
TYPE00
TYPE RUN COND
IMAGE-ADJ
MEA-CND(CAMERA1)
MEA-CND(CAMERA2)
FINAL NUM.CALC
FINAL OUTPUT COND
OBJ-TYPE I/O
OBJ-TYPE SYS.
TYPE01
TYPE(NEW)
SELECT OBJECT TYPE COND
F C1 BRT
1
TRIG CCD START
2
CCD TRIG COND
3
SHUTTER SPEED
4
SERIAL OUTPUT
5
SET SERIAL BLOCK
6
CAM NO
7
CALIBRATION
8
CALIBRATION
F C1 BRTOBJ-TYPE I/O SCREEN SAVE
1
TRIG CCD START BIN
2
CCD TRIG COND (TO NEXT SUB-MENU)
3
SHUTTER SPEED 1/00060(1/30~1/10000)
4
SERIAL OUTPUT BLOCK-ASSIGN
5
SET SERIAL BLOCK BLOCK00 MEAS0 CAM1
6
CAM NO 1(1~2)
7
CALIBRATION MANUAL
8
CALIBRATION (TO NEXT SUB-MENU)
NO
MANUAL
EDGE DTECT
F C1 BRT
CALIBRATION
SCREEN SAVE
1
CURSOR1-COORD SET (256.240)
2
CURSOR2-COORD SET (256.240)
3
SCALE 000.00
4
SCALE(UNIT) mm
5
REG EXEC
1PIXEL CBP 000.0000 mm
1mm CBM 000.0000 PIXEL