User`s manual

18-2
Communication (General Purpose Serial Interface)
18
The conditions below are what is shown when the "TRIG CCD START" is selected on the " MEAS
INP I/F" on the "I/O CONDITIONS” selection screen.
Measurement
start
Output
selection
Serial output Object type change
Auto
Parallel port --- Parallel
General purpose
serial port + USB
Response output from
command codes 11
Command codes 55
Parallel port
None --- Parallel
Computer link
SHARP/MITSUBISHI/
OMRON/YOKOGAWA
Parallel
General-purpose
serial port
Response output from
command codes 11
Parallel
General-purpose
serial port + USB
--- Command codes 10 to 12
Command codes 10 to
12
Cate-
gory
Processing function Code Function
Operation lock
status
Read 50 - Read lock/unlock condition of the operation screen.
Set 51 - Set lock/unlock for the operation screen.
English or
Japanese display
Read 52 - Read the status from the English or Japanese display.
Set 53 - Enter a change on the English or Japanese display.
Object type
number
Read 54
- Read an object type number to measure when the
measurement start input is turned ON.
Set 55
- Assign an object type number to be executed when the
measurement start input is turned ON.
Image status
Read 56
- Read the image status being monitored
(Output: Through/freeze, Brightness: Full/half).
Set 57
- Change the status of the image being monitored
(Output: Through/freeze, Brightness: Full/half).
Output image
camera
Read 58
- Read the status of the camera outputting an image for
the specified object type.
Set 59
- Set the status of the camera that is outputting an image
for the specified object type.
Shutter speed
Read 5A
- Read the shutter speed setting for the specified object
type.
Set 5B - Set shutter speed for the specified object type.
Time
Read 5C - Read the IV-S32MX/S33MX's system time.
Set 5D
- Adjust the IV-S32MX/S33MX's system time to the time
set by the host device.
Register a
reference image Assign
5E
- Measurement program: Registers reference images for
the specified object type and measurement number
(register No. 0 only).
- Image calculation: Registers reference images used for
image calculations of the specified object type.
Initialize all 60
- Set all settable conditions to their initial values (global
conditions, all object type conditions, and reference
images).
Self-diagnostic 68
- Check the controller for a hardware error.
Items to check: VRAM (read after write), SDRAM (read
afterwrite), etc.
Reset 69 - Reset the controller (the same as a power reset operation).
Manual measurement
coordinates
Read 70 - Read the coordinates detected by manual measurement.
Set 71 - Set the coordinates for manual measurement.
Individual conditions