User`s manual

20-3
Troubleshooting
20
Processing errors
[2] Causes of termination codes (when an error occurs) and remedies
When an abnormal termination code (other than 00(H)) is received, take the following measures.
Termi-
nation
code
Cause Remedy
(H)
01 The specified processing code does not exist. Check the processing code.
02
The wrong number of data items was
specified in the text.
Check the number of data items in the text.
03 The text data is outside the acceptable range. Check the text setting range.
04
The results of the check sums are not
identical.
- Check the checksoms.
- Check the communication environment for
problems such as electric noise, which may
come in on the communication line.
05
The header code (:) was not attached to the
head of the communication command.
Check whether the header code was attached
to the head of the communication command.
06 An asynchronous error has occurred.
- Check the communication environment for
problems such as electric noise, which may
come in on the communication line.
07
The communication command contains an
improper number of data items.
Check the number of data items in the
communication command.
08
An error response has been returned from the
programmable controller. (Communications
are performed normally.)
The error code is contained in the evaluation
result area, and the error code is displayed on
the monitor. Take the proper measures
according to the error code (different models
use different codes).
09
A time-out has occurred during communication
through the computer link.
- Make sure the power supply of the
programmable controller and check the
connections of the cables.
- Check the communication conditions and
computer link settings.
0A
Start address error (larger than the end
address)
Check the address.
10 SDRAM error
Replace the IV-S30 itself.
11 Flash memory error
12
No camera connected to the camera 1
connector.
Connect a camera.
13
No camera connected to the camera 2
connector.
14 VRAM error has occurred.
Replace the IV-S30 itself.
18 Flash ROM delete error
19 Flash ROM write error
1A Flash ROM verify error
20
The measurement conditions for the specified
object type have not been set.
Check the abnormal setting.
21
The setting area is larger than the screen, due
to positional correction.
22
Correction after binary conversion: The
illuminance monitor function (system) has not
been set.
23
Correction after binary conversion: The
threshold range has exceeded the specified
range.
24 No edge detection
25 A reference image has not been registered.
26 Number of labels exceed the specified amount
27 No setting for number of image lines
28 "0" subtraction error (numeric calculation)