Setting the Operating and System Conditions
2
[3] Message display
Select "YES" or "NO" to display messages on the
operation screen.
Setting to "NO" reduces the processing time.
Processing time:
YES(NUMERIC) > YES(NO NUMERIC) > NO
Display examples
1
MONITOR OUTPUT CAM1
2
CAPTURE IMG PARTIAL-IMG
3
MESSAGE DISPLAY YES(NUMERIC)
4
PATTERN DISPLAY YES
5
SHOW BINARY IMG YES
6
SHOW
θ
FIX IMG YES
7
OPS MAIN DISP YES
8
DISP CHG-EVAL NO
9
PC-MNTR NO
0
THROUGH DISPLAY NO
q
EXTENSION FUNC. NO
TYPE RUN COND SCREEN SAVE F C1 BRT
SET=SELECT A MENU ESC=BACK SEL=CHNG IMG TRG=FUNC
YES(NUMERIC)
YES(NO NUMERIC)
NO
- When "YES(NUMERIC)" is selected - When "YES(NO NUMERIC)" is selected
Can be deleted by pressing the SET key.
- When "NO" is selected
The menu bar will be displayed.
F C1 L
V*.**
(TYPE00)AREA1
OK
MEAS XXXXms XXXX-XX-XX XX:XX
MEASURE 0 CAM1 POSI-DEVIATION
X0~7 Y0~7 READY
REGST.NO 0(0~7)
X0=176.0 OK
Y0=322.0 OK
x0=+000.0 OK
y0=+000.0 OK
M0=+10000 OK
B0=+001.7 OK
X1=534.0 OK
Y1=480.0 OK
x1=+001.0 OK
y1=+001.0 OK
M1=+09999 OK
F C1 L
V*.**
(TYPE00)AREA1
OK
MEAS XXXXms XXXX-XX-XX XX:XX
MEASURE 0 CAM1 POSI-DEVIATION
X0~7 Y0~7 READY
Press the
SET key
Press the
ESC key
The menu bar will disapper.
MNU-CHG MAIN-COND CHG-MEA COND-CHG CHNG-REG SCREEN-CHG CHG-TYPE
MNU-CHG MAIN-COND CHG-MEA COND-CHG CHNG-REG SCREEN-CHG CHG-TYPE
X0~7 Y0~7 READY
MNU-CHG MAIN-COND CHG-MEA COND-CHG CHNG-REG SCREEN-CHG CHG-TYPE
YES (NUMERIC)
NO
All data will be displayed.
Data other than the numerical
result will not be displayed.
No messages will be displayed.
MESSAGE
DISPLAY
Description
YES (NO NUMERIC)