User`s manual

2-9
Setting the Operating and System Conditions
2
[7] Operation main display
When the operation screen was set to display other
screens (such as the "DISP CHG-EVAL" and "PC-
MNTR" screens), this item should be selected to return
to the main display from other screens. On the "TYPE
RUN COND" screen, select " OPS MAIN DISP" and
then "YES" on the popup menu. That will return you to
the main operation screen.
Note: When other screens are set to "YES" (such as
the " DISP CHG-EVAL" and " PC-MNTR"
screens), make sure to select "YES" from the
OPS MAIN DISP.
Press the TRG/BRT key to move the cursor to the
upper function menu. Select "SCREEN" and press the
SET key. Then select "OPS-MENU."
Select "SCREEN-CHG" on the lower menu on the
operation screen and press the SET key. "OPS-MAIN"
will be displayed in the lower right corner of the screen.
While the "OPS-MAIN" line is highlighted, press the
SET key. The main display will then change back to the
operation screen from the other screens (e.g. the JDG-
COND-CHG and PC-MNTR screens).
1
MONITOR OUTPUT CAM1
2
CAPTURE IMG PARTIAL-IMG
3
MESSAGE DISPLAY YES(NUMERIC)
4
PATTERN DISPLAY YES
5
SHOW BINARY IMG YES
6
SHOW
θ
FIX IMG YES
7
OPS MAIN DISP YES
8
DISP CHG-EVAL NO
9
PC-MNTR NO
0
THROUGH DISPLAY NO
q
EXTENSION FUNC. NO
TYPE RUN COND SCREEN SAVE F C1 BRT
SET=SELECT A MENU ESC=BACK SEL=CHNG IMG TRG=FUNC
YES
NO
1
MONITOR OUTPUT CAM1
2
CAPTURE IMG PARTIAL-IMG
3
MESSAGE DISPLAY YES(NUMERIC)
4
PATTERN DISPLAY YES
5
SHOW BINARY IMG YES
6
SHOW
θ
FIX IMG YES
7
OPS MAIN DISP YES
8
DISP CHG-EVAL NO
9
PC-MNTR NO
0
THROUGH DISPLAY NO
q
EXTENSION FUNC. NO
TYPE RUN COND SCREEN SAVE F C1 BRT
OPS-MENU
MAIN
SELECT
RETURN
OK
X0∼7
□□□□□□□□
 Y0∼7
□□□□□□□□
 READY
MNU-CHG MAIN-COND CHG-MEA COND-CHG CHNG-REG SCREEN-CHG CHG-TYPE
OPS-MAIN
PC-MNTR
PC-MNTR 2
MEAS
XXXXms 2001-10-14 10:38
MEASURE 0 CAM1 POSI-DEVIATION
(TYPE00) AREA1
F C1 DRK
V*.**
C1=002.2 OK
C2=100.0 OK